Download Print this page
Dixon BAYCO BC Series Maintenance Instructions Manual

Dixon BAYCO BC Series Maintenance Instructions Manual

2” bayonet style dry disconnects

Advertisement

Available languages

Available languages

Quick Links

MAINTENANCE INSTRUCTIONS
BAYCO BC, BS & BSS SERIES 2" BAYONET STYLE
Aluminum
U S A:
Dixon Bayco USA
Chestertown, Maryland
Phone: 410-778-2000
Fax: 410-778-4702
Toll Free: 800-355-1991
40233PA
DRY DISCONNECTS
Model Numbers
BS61-200 ............ 2" Buna Seal, Alum Body, 90 swivel
BS62-200 ............ 2" Viton Seal, Alum Body, 90 swivel
BSS61-200 .......... 2" Buna Seal, Alum Body, Straight swivel
BSS62-200 .......... 2" Viton Seal, Alum Body, Straight swivel
BC61-200............ 2" Buna Seal, Alum Body, No swivel
BC62-200............ 2" Viton Seal, Alum Body, No swivel
For Sales & Service Contact
Dixon Bayco
For
A DIXON COMPANY
CANADA:
Dixon Bayco Limited
Barrie, Ontario
Phone: 705-436-1125
Fax: 705-436-6251
Toll Free: 800-355-1991
1
JULY 2009

Advertisement

loading

Summary of Contents for Dixon BAYCO BC Series

  • Page 1 BSS62-200 ..2” Viton Seal, Alum Body, Straight swivel BC61-200.... 2” Buna Seal, Alum Body, No swivel BC62-200.... 2” Viton Seal, Alum Body, No swivel For Sales & Service Contact Dixon Bayco A DIXON COMPANY U S A: CANADA: Dixon Bayco USA Dixon Bayco Limited...
  • Page 2 BS SERIES SHOWN WITHOUT BUMPER RING 40233PA JULY 2009...
  • Page 3 BSS SERIES Figure 1 40233PA JULY 2009...
  • Page 4 BASIC BOM FOR BS61 (BUNA-N) SERIES ITEM PART NO. MATERIAL DESCRIPTION NOTES 40136HC ALUM BODY 40138SS SHAFT 40139SS FOLLOWER 40140SS LEVER 40141SS LINK 40142SS BENT LINK 40143SS STEM 40144SS INTERLOCK PIN 40145SS LOCK RING 40146HC ALUM NOSE PIECE 40147RA ALUM POPPET 40148SS COILED PIN...
  • Page 5 OPERATING INSTRUCTIONS: These products are designed to operate as Dry Disconnect couplings. They are to be used in place of standard couplings when it is desired to prevent product from spilling from the fittings upon disconnect. This product is not intended to be the primary flow control or flow shut off device. Just as with standard non-dry disconnect fittings, it is intended that a flow control and flow shutoff valve will be installed in the system.
  • Page 6 5. Rotate the LEVER counterclockwise to open the POPPET. Remove the POPPET by first removing the COTTER PIN that secures it then unthreading the POPPET from the STEM. 6. Remove the NOSE PIECE, 2 WAVE SPRINGS and 1 WAVE SPRING WASHER. 7.
  • Page 7 7. Lubricate the O-RING and outside diameter of the NOSE PIECE and press the assembled NOSE PIECE through the hole in the LOCK RING and into the body. 8. Slide the STEM and BENT LINK assembly into the BODY from the swivel end. The STEM will pass through the hole in the cast boss in the BODY.
  • Page 8: Test Procedure

    23. Lubricate the BEARING STRIP and two O-RINGS and using a rotating motion, push the ELBOW or STRAIGHT SWIVEL onto the BODY. 24. Hold the ELBOW stationary with the opening for the balls pointing upward, and while rotating the BODY, insert the same number of balls that were removed. 25.
  • Page 9: Repair Kits

    BUMPER RING SWIVEL SEALS BS61 O-RING SWIVEL SEALS BUNA-N BEARING STRIP SWIVEL BS62 O-RING SWIVEL SEALS VITON BEARING STRIP SWIVEL DIXON BAYCO WARRANTY: For Warranty Information, please refer to the inside back cover of the latest Dixon Catalog. 40233PA JULY 2009...
  • Page 10 E-mail: enquiries@dixoneurope.co.uk Fax: 410-778-4702 Fax: 705-436-6251 www.dixonvalve.com www.dixoneurope.co.uk Toll Free: 800-355-1991 Toll Free: 800-355-1991 Asie et Pacifique: Dixon (Asia Pacific) Pty Ltd Wingfield, South Australia Téléphone +61 8 8202 6000 Fax: +61 8 8202 6099 E-mail:enquiries@dixonvalve.com.au www.dixonvalve.com.au 40233PA JULY 2009...
  • Page 11 SÉRIE BS VU SANS ANNEAU PARE-CHOC 40233PA(fr)
  • Page 12 SÉRIE BSS 40233PA(fr)
  • Page 13 Figure 1 40233PA(fr)
  • Page 14 MATÉRIAUX DE BASE POUR SÉRIE BS61 (BUNA-N) PIÈCE QTÉ #DE LA MATÉRIAUX DESCRIPTION NOTES PIÈCE 40136HC ALUM CORPS 40138SS ARBRES 40139SS FOULOIR 40140SS LEVIER 40141SS LIEN 40142SS LIEN PLIÉ 40143SS TIGE BROCHE DE 40144SS VERROUILLAGE ANNEAU DE 40145SS VERROUILLAGE 40146HC ALUM 40147RA ALUM...
  • Page 15 Utilisez 40163VI 40164SS GOUPILLE BANDE POUR 40165NY NYLON ROULEMENT 40166VY ANNEAU PARE-CHOC 40233PA(fr)
  • Page 16: Instructions D'opération

    INSTRUCTIONS D’OPÉRATION: Ces produits sont conçus pour opérer comme un raccord rapide pour transfère sécurisé. Ils doivent être utilisés à la place des coupleurs standards si vous voulez empêchez un produit de se renverser hors de l’accouplement lors de la déconnection. Ce produit n’est pas conçu pour être l’arrêt primaire du débit.
  • Page 17 2. Retirez l’anneau pare-choc en le réchauffant avec un chauffe-industriel pour ramollir le matériel. 3. Appuyez sur l’anneau de verrouillage et tournez au sens des aiguilles d’une montre pour le déloger du goujon baïonnette. 4. Retirez le goujon baïonnette en retenant la tête avec une clé “Allen” et desserrant le contre- écrou qui tien le goujon baïonnette.
  • Page 18 3. Insérez la goupille de verrouillage dans le trou de la pièce pointant vers le haut et l’extrémité du coupleur. 4. Insérez l’anneau de verrouillage dans la pièce de façon que l’encoche de l’anneau de verrouillage enfourche la goupille. Tournez l’anneau de verrouillage dans le sens des aiguilles d’une montre jusqu’à...
  • Page 19 fermée, commencez à desserrez légèrement le clapet jusqu’à ce que le clapet tournera dans une position fermée. Si les trous de la tige s’alignent avec l’entaille du clapet, insérez la goupille. 19. Vérifiez le fonctionnement du levier et du clapet et si vous êtes satisfait, écartez la goupille. 20.
  • Page 20 2. Pressurisez le coupleur entre 3 P.S.I.G. et 5 P.S.I.G. Submerger la pièce sous l’eau et vérifiez pour des fuites. (Test avec pression abaissé) 3. Augmentez la pression jusqu’à 30 P.S.I.G. pendant qu’elle est toujours sous l’eau et vérifiez pour des fuites. (Test avec pression élevé) 4.
  • Page 21 ROULEMENT PIVOT BS62 JOINT TORIQUE JOINT DU PIVOT BANDE DE VITON ROULEMENT PIVOT GARANTIE DIXON: Pour plus d’informations complètes sur la garantie, s’il vous plait se référer à la couverture intérieure de la dernière page du dernier catalogue Dixon. 40233PA(fr)