4. CONTROLS

4.1
I
C
NTEGRATED
ONTROL
All units are equipped with an integrated control, located under the unit, in front of the electrical
compartment. Use the push button (1) to control the unit. The LED (2) will then shows on
which mode the unit is in.
Refer to table below to see how to operate the unit using its integrated control.
If a problem occurs during the unit operation, its integrated control LED (2) will blink. The color of the blinking light depends on the type
of error detected. Refer to Section 11 Troubleshooting on last page for further details.
4.1.1 B
OOT SEQUENCE
The unit boot sequence is similar to a personnal computer boot sequence. Each times the unit is plugged after being unplugged, or
after a power failure, the unit will perform a 30-second booting sequence before starting to operate. During the booting sequence, the
integrated control LED will light GREEN or AMBER for 5 seconds, and then will shut off for 2 seconds. After that, the LED will light RED
for the rest of the booting sequence. During this RED light phase, the unit is checking and resetting the motorized damper position.
Once the motorized damper position completely set, the RED light turns off and the booting sequence is done.
NOTE: No command will be taken until the unit is fully booted.
4.2 E
C
LECTRICAL
ONNECTION TO
For more convenience, this unit can also be controlled using an optional main wall control.
NOTES: 1. The integrated control must be turned OFF to use an optional main control.
2. If an optional auxiliary control is used, if activated, this auxiliary control will override the optional main control.
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical shock or
damage of the wall control or electronic module inside the unit.
Never install more than one optional main wall control per unit. Make sure that the wires do not short-circuit between themselves
or by touching any other components on the wall control. Avoid poor wiring connections. To reduce electrical interference
(noise) potential, do not run wall control wiring next to control contactors or near light dimming circuits, electrical motors,
dwelling/building power or lighting wiring, or power distribution panel.
Use the terminal connector included in the installation kit to perform the electrical
connection for main and optional wall controls. Check if all wires are correctly inserted in
their corresponding holes in the terminal block. (A wire is correctly inserted when its
orange receptacle is lower than another one without wire. On picture beside, wire A is
correctly inserted, but not wire B.)
P
RESS ON PUSH BUTTON
O
NCE
T
WICE
T
T
HREE
IMES
O
W
C
PTIONAL
ALL
ONTROLS
0
LED C
OLOR
A
U
MBER
NIT IS ON
G
U
REEN
NIT IS ON
N
L
O
IGHT
!
WARNING
CAUTION
- 17 -
WARNING
Risk of electric shock. Before performing
any maintenance or servicing, always
toujours l'appareil avant d'entreprendre
disconnect the unit from its power source.
des travaux d'entretien ou de réparation.
CAUTION
Unscrew both screws to open the electrical
Dévisser les deux vis pour ouvrir le compartiment
compartment. To completely remove, detach
électrique. Pour retirer complètement, le
from its retention wire inside.
détacher de son fil de rétention intérieur.
No light
OFF or remote controled
Amber light
LOW speed
Green ligh
HIGH speed
Blinking light
See User Manual
Sans lumière
Arrêté ou contrôlé
par contrôle mural
Lumière ambre
Basse vitesse
Lumière verte
Haute vitesse
Clignotant
Voir guide d'utilisation
1 2
VD0182
R
ESULTS
L
S
OW
PEED
H
S
IGH
PEED
U
OFF
NIT IS
A
B
VE0106
AVERTISSEMENT
Danger d'électrocution. Débranchez
ATTENTION