Dimensions & Weights - Toshiba TMC7 Series Product Manual

Table of Contents

Advertisement

3.2
Dimensions & Weights
TMC7-007 ~ TMC7-030 (2.4kg)
98 (3.86)
82 (3.23)
TOSHIBA INTERNATIONAL C ORPO RATIO N PTY
LTD - AUSTRALIA
Ready
Run
RESET
Current Ramp
Motor FLC
TRIP CODES
(%FLC/Ramp Time)
(% TMC7 FLC)
Ready
5s 15s
x 1. Power
2s
70%
80%
Circuit
x 2. Excess
15
2s
Start Time
5s
5s
60%
90%
x 3. Motor
2s
15
50%
Overload
OFF
100%
x 4. Motor
Thermistor
Current Limit
Soft Stop
x 5. Current
(% Motor FLC)
(Seconds)
Imbalance
350%
10s
x 6. Supply
8s
12s
Frequency
300%
400%
6s
14s
x 7. Phase
Rotation
4s
16s
x 8. Comms
2s
20s
250%
450%
No
Failure
Soft Stop
Aux
Motor Trip
Excess
Class
Relay
Start Time
10
10s
8
12
8s
12s
6s
6
14
14s
TMC
7
4
16
4s
16s
2
20
2s
OFF
OFF
20s
SE RIES
SOFT STARTER
Phase
Rotation
Relay Outputs
Control Supply
380 - 440VAC or
Motor
Thermistor
Stop
Start
110 - 240VAC
Input
N.O.
N.O.
C1
C2
R33 R34
R43 R44 02 01 A2 A1 A3
TMC7-037 ~ TMC7-055 (4.3kg)
145 (5.71)
124 (4.88)
TOSHIBA INTERNATIONAL COR PORATION PTY
LTD - AUSTRALIA
Ready
Run
RESET
Current Ramp
Motor FLC
TRIP CODES
(%FLC/Ramp Time)
(% TMC7 FLC)
Ready
x 1. Power
5s
2s
15s
70%
80%
Circuit
x 2. Excess
15
2s
Start Time
5s
5s
60%
90%
x 3. Motor
2s
15
50%
Overload
OFF
100%
x 4. Motor
Thermistor
Current Limit
Soft Stop
x 5. Current
(% Motor FLC)
(Seconds)
Imbalance
350%
10s
x 6. Supply
8s
12s
Frequency
300%
400%
6s
14s
x 7. Phase
Rotation
4s
16s
x 8. Comms
2s
20s
250%
450%
No
Failure
Soft Stop
Aux
Motor Trip
Excess
Class
Relay
Start Time
10
10s
8
12
8s
12s
6s
6
14
14s
TMC
7
4
16
4s
16s
2
20
2s
20s
OFF
OFF
SERIES
SOFT STARTER
Phase
Rotation
Relay Outputs
Control Supply
Motor
380 - 440VAC or
Thermistor
Input
N.O.
N.O.
Stop
Start
110 - 240VAC
C1
C2
R33 R34
R43 R44 02 01 A2 A1 A3
TMC7-075 ~ TMC7-110 (6.8kg)
202 (7.95)
160 (6.30)
TOSHIBA INTERNATIONAL CORPORATION PTY
LTD - AUSTRALIA
Ready
Run
RESET
Current Ramp
Motor FLC
TRIP CODES
(%FLC/Ramp Time)
(% TMC7 FLC)
Ready
x 1. Power
5s
2s
15s
70%
80%
Circuit
x 2. Excess
15
2s
Start Time
5s
5s
60%
90%
x 3. Motor
2s
15
50%
Overload
OFF
100%
x 4. Motor
Thermistor
Current Limit
Soft Stop
x 5. Current
(% Motor FLC)
(Seconds)
Imbalance
350%
10s
x 6. Supply
8s
12s
Frequency
300%
400%
6s
1 4s
x 7. Phase
4s
16s
Rotation
2s
20s
x 8. Comms
250%
450%
No
Failure
Soft Stop
Motor Trip
Aux
Excess
Class
Relay
Start Time
10
10s
8
12
8s
12s
6
14
6s
14s
TMC
7
4
16
4s
16s
2
20
2s
20s
OFF
OFF
S ER IE S
SOFT STARTER
Phase
Rotation
Relay Outputs
Control Supply
380 - 440VAC or
Motor
Thermistor
Input
N.O.
N.O.
Stop
Start
110 - 240VAC
C1
C2
R33 R34
R43 R44 02 01 A2 A1 A3
Page 5
710-02887-00A
165 (6.50)
C
23
(0.9)
193 (7.60)
214 (8.43)
23
(0.9)
37
37
(1.46)
(1.46)
51
51
(2.0)
(2.0)
SERIES OVERVIEW
TMC7 Series

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents