11. M-NET CONTROL
11-4-3-6. ME remote controller, Multi-refrigerant-system, System Controller at TB7 side, Lossnay, Booster for long M-NET wiring
PURY
OC
OS
TB7
TB7
51
52
CN40
CN41
CN40
CN41
DipSW5-1
DipSW5-1
ON
ON
TB3
TB3
BC controller
(Main)
53
TB02
PSU
Power supply
unit (PSU)
(PAC-SC51KUA)
*1
BC controller
93
TB02
000 or 201
SC
*1 System controller should connect to TB7 at Outdoor and use power supply unit together in Multi-Refrigerant-System.
For AG-150A-A, 24VDC should be used with the PAC-SC51KUA. For AE-200A, AE-50A, and EW-50A the power supply unit PAC-SC51KUA is unused.
NOTE:
1. Outdoor units OC and OS in one refrigerant circuit system are automatically detected.
OC and OS are ranked in descending order of capacity. If units are the same capacity, they are ranked in ascending order of their address.
2. M-NET power is supplied by the Outdoor unit at TB3, while Indoor unit and ME R/C consume the M-NET power for transmission
use. The power balance is needed to consider for long M-NET wiring. Details refer to 11-3. "System configuration restrictions".
3. Indoor units should be set with a branch number.
4. Assign an address to each of the sub BC controllers which equals the sum of the smallest address of the indoor units that are connected
to each sub BC controller and 50.
When the address assigned to sub BC controller overlaps those of any other units including outdoor units (OC/OS) or main BC controller,
sub BC controller will be given priority to have the address.
11-4-3-7. Example: BC, BC sub
PURY
OS
OC
52
51
CN40
CN41
CN40
CN41
DipSW5-1
DipSW5-1
OFF
OFF
TB3
TB3
MEES19K180
PURY
OC
TB7
91
CN40
CN41
DipSW5-1
ON
TB3
TB3
Group 1
Indoor unit
01
02
TB5
TB5
101
102
ME R/C
ME R/C
Group 31
Group 32
Indoor unit
41
42
TB5
TB5
141
142
ME R/C
ME R/C
.
NOTE
• Indoor units should be set with a branch number.
• BC (main) address = O/U address + 1
• BC (sub) address = Lowest address within the indoor units connected to the BC controller (sub) + 50
• If applicable, set the sub BC controllers in an PURY system in the following order :
(1) Indoor unit to be connected to the BC controller (Main)
(2) Indoor unit to be connected to the BC controller (No.1 Sub)
(3) Indoor unit to be connected to the BC controller (No.2 Sub)
Set the address so that (1)<(2)<(3)
53
BC controllers
TB02
CMB-P-NU-JA1(main)
01
02
TB5
TB5
TB5
101
Group 1
PURY
OS
OC
TB7
TB7
92
96
CN40
CN41
CN40
CN41
DipSW5-1
DipSW5-1
ON
ON
TB3
Group 2
BC controller
(Sub)
03
80
TB5
TB02
Lossnay
Group 33
Interlocked with
M-NET address 42
43
TB5
: M-NET wiring
54
BC controllers
TB02
CMB-P-NU-KB1(No.1 sub)
04
05
03
TB5
TB5
104
Group 2
Hyper Heating Inverter R2-Series
Group 21
30
TB2
TB3
TB5
Transmission Booster
PAC-SF46EPA-G
130
ME R/C
Group 34
44
45
TB5
TB5
144
145
ME R/C ME R/C
ME R/C
: Piping
57
BC controllers
TB02
CMB-P-NU-KB1(No.2 sub)
06
07
TB5
TB5
106
Group 3
Group 4
195
08
TB5
107
94