... the temperature cut-out
actuates
... the alarm sounds
6

Spare parts list

Pos.
Description
3
Strainer
32
Guide clamp (rotary
hinge)
40
Non-return flap
41
Screw-in element
48
Trenched washer
49
Floater
7

Accessories

For the pump of this series is a float-switch available for backfitting (only for model STANDARD), non-return
flap (serial at models "S" , "SA", and "F"), residual-current-operated protective device (RCD), mooring rope,
couplings (e.g. Geka, STORZ C) and much more. Ask our customer care for more details.
8

Disposal

This product and parts of it must be disposed according local, applicable regulations or to be returned to the
manufacturer.
16
Coil too hot because power
intake too high
Temperature of pumped
mediums too high (over
45°C)
Intake exceeds pumping
speed of pump
Malfunction on float
Pump blocked
Motor defective
Pressure line blocked
STANDARD
Eliminate sluggishness or pump
blockage
If motor defective: This
work may only be done at
the factory
Have motor repaired
Observe temperature limits
Reduce intake, use more powerful
pump if necessary
Make float accessible and clean
Remove foreign body from casing
and/or running wheel
This work may only be
done at the factory
Have motor repaired
Clean pressure line
S
SA
02 00 070
02 00 080
02 00 023
02 00 090
02 00 236
02 00 205