Troubleshooting Instructions
If a fault occurs, count the number of red flashes between pauses and refer to the table below:
Red Flashes
Specifications
DC Output – see Operating Instructions
QuiQ Model:
912-2400
628089
Voltage-nom (V)
24
Voltage-max (V)
34
Current-max (A)
25
Battery Type
Lead acid (Wet / AGM / GEL)
Reverse Polarity
Electronic protection – auto-reset
Short Circuit
AC Input
All models
Voltage-max (Vrms)
Frequency (Hz)
Current - max (Arms)
AC Power Factor
Mechanical
All models
Dimensions
28.0 x 24.5 x 11.0 cm (11 x 9.7 x
Weight
Environmental
Operating
-30°C to +50°C (-22°F to 122°F),
Temperature
derated above 30°C, below 0°C
Storage Temperature
-40°C to +70°C (-40°F to 158°F)
AC input connector
(require 1.8m localized cord)
DC output
OEM specific w/ 12AWG wire
Product warranty is dependent on model - please contact dealer of original equipment for warranty service.
Note: This is a Class A product. In a domestic environment this product may cause radio interference, and the user may be required to take adequate measures.
2012 © Delta-Q Technologies Corp. All rights reserved. PN: 710-0141 Rev 1
Cause
Charge Enable Fault or
Battery Temperature Fault
Battery Voltage Too Low or High
Charge Timeout caused by battery
pack not reaching required voltage.
Charger output was reduced due to
high temperatures.
Check Battery: battery could not be
trickle charged up to minimum voltage
Over-Temperature: Charger shut
down due to high internal
temperature.
Charger Internal Fault
912-3600-07
912-4800-14
628102
624206
36
48
51
67
21
18
Electronic current limit
85 – 265
45 - 65
9.5A @ 120VAC
5A @ 230VAC
>0.99 at 120VAC
>0.98 at 230VAC
4.3")
<5 kg (11 lbs)
Enclosure: IP66
IEC320/C14
Solution
Check connector contacts and retry.
Check that battery temperature is between
-10°C and +50°C.
Check battery size and condition of
batteries.
Check for loose connections or corrosion.
Operate charger at a lower ambient
temperature or increase cooling air flow.
Check for shorted or damaged cells.
Ensure sufficient cooling air flow and reset
charger (interrupt AC power for 15
seconds).
Reset charger (interrupt AC power for 15
seconds). Return to qualified service depot
if fault persists.
Operation
All models
Battery Temperature
Compensation
Maintenance Mode
Auto-restart if V < 2.08V/cell
Regulatory
Safety
EN 60335-2-29
Safety of Appliances/ Battery Chargers
st
UL2202 (1
Ed.)
EV Charging System Equipment
UL1564 3rd Ed.
Industrial Battery Charger
CSA- 107.2
Battery Chargers- Industrial
Emissions
FCC Part 15/ICES
Unintentional Radiators Class A
003
EN 55011
Radio disturbance characteristics
EN 61000-3-2
Limits for harmonic current emissions
EN 61000-3-3
Limits of voltage fluctuations and
Immunity
EN 61000-4-2
Electrostatic discharge immunity
EN 61000-4-3
Radiated, radio-frequency,
EN 61000-4-4
Electrical fast transient/burst immunity
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
Voltage variations immunity
A
PPENDIX
w/Default Algo 1
Automatic
or 30 days elapse
(Class A)
flicker
EMF immunity
Surge immunity
Conducted Immunity
A
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF