6.2 Flash duration

DIP switches named FLASH DUR 1, 2 select the Flash duration. The Flash duration tells the CSW how long
each flash is.
(off,off) Selects 100ms flash duration. (1/10 of a second)
(on,off) Selects 250ms flash duration. (¼ of a second)
(off,on) Selects 500ms flash duration. (½ of a second)
(on,on) Selects CASA compliant flash duration (Duty cycle: 2/3 ON, 1/3 OFF)
IMPORTANT: Only use Steady Burn, 20 FPM, 30FPM, 40 FPM or 60 FPM base sequences with the CASA
compliant flash duration setting! Other base sequences may cause undesired operation.

6.3 Flash mode

DIP switches named FLASH MODE 1, 2 select the flash mode. The flash mode setting effects the method
with which the flashes are directed to the outputs.
(off,off) All enabled outputs flash together.

6.4 Test mode

DIP switch named TEST MODE selects the test mode. Test mode makes CSW-DCW system testing easier.
Set the test-mode DIP switch to ON to enter test mode. In test mode output channel 1 can set ON from the
Option 1 DIP. Option 2 DIP turns on the channel 2. Same applies to Option 3,4 DIP switches and output
channels 3,4. In test mode, the CSW-DCW shortens the photocell timing periods. By physically blocking the
photocell all the channels are set to night mode with a short delay.
After using test mode, turn off the Option 1-4 DIP switches. If they are not off, the CSW will not function
normally.

6.5 Photocell sensitivity

DIP switches named PHOTOCELL 1, 2 select the photocell sensitivity.
(off,off) Photocell operation disabled
(on,off) Photocell enabled, disables outputs if light level above 400 Lux.
(off,on) Photocell enabled, disables outputs if light level above 800 Lux.
(on,on) Photocell enabled, disables outputs if light level above 1600 Lux.
© Obelux Oy 2016
In production environment, use test mode with appropriate caution.
Obelux Oy, Kutomotie 6 B, 00380 Helsinki FINLAND
Technical information in this document is subject to change without notice.
CSW-DCW – Manual