Samsung MIM-E03CN Installation Manual page 15

Air to water heat pump control kit
Hide thumbs Also See for MIM-E03CN:
Table of Contents

Advertisement

5. Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape.
Method 1
Insulation tape
40 mm
6. Apply heat to the contraction tube to contract it.
Method 1
Contraction tube
7. After tube contraction work is completed, wrap it with the insulation tape to finish.
Three or more layers of insulation are required.
Method 1
Insulation tape
• Make sure that the connection parts are not exposed to outside.
• Be sure to use insulation tape and a contraction tube made of approved reinforced insulating materials that have
CAUTION
the same level of withstand voltage with the power cable. (Comply with the local regulations on extensions.)
• In case of extending the electric wire, please DO NOT use a round-shaped Pressing socket.
- Incomplete wire connections can cause electric shock or a fire.
WARNING
Method 2
Insulation tape
35 mm
Method 2
Contraction tube
Method 2
Insulation tape
15