4.4
RS-485
The RS-485 Interface is shown in Figure 4-5. The RS-485 interface provides a direct connection
to the Iridium Edge Pro's device's RS-485 signals. The interface, labelled as RS-485, reference
designator J12, is a 4-position screwless, spring loaded terminal block that supports 20-26 AWG
wire.
4.5

CAN Bus

The CAN Bus Interface provides a direct connection to the Iridium Edge Pro's device's CAN Bus
signals. The interface, labelled as CAN BUS, reference designator J12 on the TIC) is a 4-position
screwless, spring loaded terminal block, as shown in Figure 4-6. The terminal block can be used
with 20-26 AWG wire and provides a direct connection to the Iridium Edge Pro CAN Bus signals.
4.6

Input/Output

The Iridium Edge Pro has two Digital or Analog inputs (IN_1 and IN_2) and two Digital
Input/Outputs (IO_3 and IO_4). Refer to the Iridium Edge Pro Hardware Developer Guide [
Reference 1] for complete details on the I/O interface as well as the IO_RET1 and IO_RET2
ground return that can be optionally used with the I/Os.
The TIC supports both Remote I/O testing and Local I/O testing. With Remote testing, the Iridium
Edge Pro I/Os are connected directly to external devices, remote from the TIC. With Local the TIC
provides test capabilities to both monitor digital I/Os or set digital and analogue inputs. The switch
settings as defined in Table 4-1: Local/Remote Selection Switchescan be set to LOCAL or
REMOTE.
Controlled for export under the EAR. See front cover for use and disclosure statement.
Iridium Satellite LLC Proprietary and Confidential Information
CD-200134-00 Iridium Edge Pro Development Kit Guide v2.0
Figure 4-5: RS-485 Interface
Figure 4-6: CAN Bus Interface