2.3. Cable options / Kabeloptionen
2.4. Assembly / Montage
−
Loosen the screw (Allen Key, 3mm) of the R500 clamp
−
Open the clamp and position the R500 at the handlebar
(22.2 mm)
−
Close the clamp of R500 and orientate ergonomically
−
The cable must run through the groove inside the clamp
−
Tighten the screw of R500 clamp with 0.40 Nm
−
If an EOX
®
VIEW 1200 is used connect the
plug of R500 with the plug of EOX
−
If no EOX
®
VIEW 1200 is used connect the
plug of R500 with the plug of the e-system
2.5. Technical details / Technische Details
Specifications
Color (housing)
Material
Weight
Mounting options
Handlebar diameter
Communication interfaces
CAN communication
baudrate
FW update
Usability
Power supply
Operating voltage
Operating power consumption < 50 mA
Display
Backlight
Sensors
RTC accuracy
60
cm
®
VIEW 1200
Black
ABS (Housing),
PA+GF (Arm), TPU (Pads)
33.8 g
Handlebar (left)
22.2 mm
CAN, BLE
250 / 250 / 1000 Kbps
(min / typ / max)
CAN, BLE
stand-alone
by E-Bike
6 / 12 / 16 V (min / typ / max)
LED indicator (9 x RGB)
(buttons)
Ambient Light, RTC
+/- 1 sec/day @ 25 °C
−
Schraube (Innensechskant, 3mm) der R500 Schelle
lösen
−
Schelle der R500 öffnen und am Lenker positionieren
(22.2 mm)
−
Schelle der R500 schließen und ergonomisch ausrichten
−
Kabel muss in vorgesehener Führung innerhalb der
Schelle verlaufen
−
Schraube der R500 Schelle mit 0.40 Nm festziehen
−
Wenn ein EOX
®
VIEW 1200 verwendet wird,
den Stecker der R500 mit dem Stecker des
EOX
VIEW 1200 verbinden
®
−
Wenn kein EOX
VIEW 1200 verwendet wird,
®
den Stecker der R500 mit Stecker des E-Systems
verbinden
Operating temperature
Storage temperature
IP rating
Certification
-10 / 25 / 60 °C
(min / typ / max)
-20 / 25 / 70 °C
(min / typ / max)
IPX6K, IPX7
CE, FCC, ROHS, REACH,
EN15194