DECLARATION OF CONFORMITY
1.
Product model: IM1800IFG
2.
Name and address of the manufacturer or his authorised representative:
3.
This declaration of conformity is issued under the sole responsibility of the manufacturer.
4.
Object of the declaration:
Equipment: 1800W Inverter Generator
Brand name: IMPAX
Model/type: IM1800IFG
5.
The object of the declaration described above is in conformity with the relevant statutory requirements:
Supply of Machinery (Safety) Regulations 2008
Electrical Equipment (Safety) Regulations 2016
Electromagnetic Compatibility Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment
Regulations 2012
Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001
Measured Sound Power Level: 89dB(A), Declared Guaranteed Sound Power Level: 92dB(A)
6.
References to the relevant designated standards used or references to the other technical
specifications in relation to which conformity is declared:
BS EN 8528-13
BS EN 55012
BS EN 61000-6-1
BS EN ISO 3744
7.
The person authorized to compile the technical file:
Name: Robert Redfern
Address: Nap Brands Ltd. Office 20, Fleming Court Business Centre, Leigh Road, Eastleigh,
Hampshire SO50 9YN
Signed for and on behalf of:
Authorised Representative
Robert Redfern, Technical Manager
04/03/2021
After sales support: Tel: 0344 264 2485 Website: www.impaxpowertools.com
NAP BRANDS LTD. Office 20, Fleming Court Business Centre,
Leigh Road, Eastleigh, Hampshire SO50 9YN
Tel: +44 (0)23 8064 9650. Email: sales@napbrands.co.uk
21
Need help?
Do you have a question about the IM1800IFG and is the answer not in the manual?
Questions and answers
Please can you tell me the exact spec/size for the fuel line (between fuel tank and carbuerator) for a Impact Inverter Generator IM 1800 IFG, and the appropriate clips necessary? Thank you very much.
The document states that the fuel line is attached to a barb using a tubing clamp and can be removed with pliers. However, it does not specify the exact size of the fuel line or the type or size of the tubing clips needed.
Therefore, based on the provided information:
Specifications and size of the fuel line: NOT SPECIFIED
Type of clips needed: Tubing clamp (exact type and size NOT SPECIFIED)
This answer is automatically generated
My impax 1800w inverter genorator starts fine but red overload light stays on and green light stays on too. Is there some way to reset.
To reset the overload light on an Impax IM1800IFG inverter generator, follow these steps:
1. Disconnect the Load – Unplug all connected appliances from the generator's AC output sockets.
2. Check the Overload Indicator – If the red overload indicator light is ON, the generator has detected an overload or a short circuit.
3. Turn Off the Generator – Switch the engine switch to the STOP position.
4. Check for Issues – Ensure the connected appliances do not exceed the generator’s rated capacity and inspect for any short circuits.
5. Restart the Generator – Follow the standard starting procedure:
- Turn the fuel valve to the ON position.
- Turn the engine switch to the ON position.
- Set the choke lever to the CLOSED position if the engine is cold.
- Pull the recoil starter cord until the engine starts.
- Once running smoothly, set the choke lever to the RUN position.
6. Reconnect the Load – Plug in appliances one at a time, ensuring the total load does not exceed the generator's capacity.
If the overload light remains ON after following these steps, further troubleshooting may be required.
This answer is automatically generated