Description - Siemens SIMATIC NET Installation Manual

Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Introduction
1.2 Description
Power Supply
1.2

Description

The RUGGEDCOM RS900F features various ports, controls and indicator LEDs on the
front panel for connecting, configuring and troubleshooting the device.
1
2
3
4
5
1
2
3
4
5
6
7
8
2
20 AWG Galvanized Steel
DIN or panel mounting options provide secure mechanical reliability
[Optional] Conformal coated printed circuit boards
Fully integrated power supply
Universal high-voltage range:
125-250 VDC or 100-240 VAC (Hazardous Environments)
88-300 VDC or 85-264 VAC (Non-Hazardous Environments)
Dual LO DC inputs: 24 or 48 VDC
Terminal blocks for reliable maintenance free connections
CSA/UL 62368-1 safety approved to 85 °C (185 °F)
POWER LED
ALARM LED
RESET Button
[Optional] Copper (10/100Base-TX) or Fiber Optic (100Base-FX) Ethernet Ports
Copper (10/100Base-TX) Ethernet Ports
RS232 Console Port (Serial)
Failsafe Alarm Relay
Chassis Ground Connection
4
6
7
8
9
RUGGEDCOM RS900F
Installation Manual, 04/2021, C79000-G8976-1350-07