Page 2
Taste AN/AUS - EINSTELLUNGEN Drücken und Loslassen: Schaltet das Gerät an und ab. Drücken und gedrückt haltend (2 Sekunden oder länger): Messwerteinstellung für den absoluten Messmodus. Messrahmen metrisch = 0, 25, 50, 75mm..275mm. Messrahmen Zoll = 0 , 1", 2" ,3"..11".
Page 3
Art. 8427 Digital - Micrometer FUNCTIONAL ELEMENTS 1. LCD display 2. Friction drive 3. Quick drive 4. ABS/ INC - UNIT key 5. ON/OFF - SET key 6. Data output LCD DISPLAY "INC": Relative measuring mode "in" - Unit: inch "mm"...
Page 4
ON/OFF..SET KEY Press and release: Power on/off. Press and hold (2sec. or more) Datum setting for absolute measurement. Origin of metric is 0, 25, 50, 75mm..275mm. Origin of inch is 0 , 1", 2" ,3"..11". Sets datum automatically after battery reset. ABS/INC..UNIT KEY Press and release: Absolute and relative measuring mode conversion;...
Page 5
Norme appliquée: Normas aplicadas: EN 61326-1:2006 Verification No.:GZEM120400113901V/MD310-710 Wermelskirchen, den 05.06.2013 ppa. Frank Schottke, Prokurist BGS technic KG, Bandwirkerstrasse 3, D-42929 Wermelskirchen SW-Stahl und Werkzeugvertriebs GmbH Tel. +49 (0) 2191 / 46438-0 ax +49 (0) 2191 / 46438-40 : l i...
Need help?
Do you have a question about the 8427 and is the answer not in the manual?
Questions and answers