Note: Refer to Diagrams B and E for Steps 8 – 12.
8. Position Electrical Box (4) on the wall so the top is within 12" of the Sensor Washer (7 or 8) and
within 28" of the Solenoid Wire Connector (42) and secure with 2 Wood Screws (10). Drywall
Anchors (11) may be used if securing to drywall.
9. Connect Sensor Wire (43) to Sensor Washer (7 or 8) and Solenoid Wire (44) to Solenoid Wire
Connector (42).
Note: Sensor Washer (7 or 8) may be bent to accommodate Sensor Wire (43).
10. Route Sensor Wire (43) and Solenoid Wire (44) so they do not come in contact with each other, with
the hoses or with any metal. Wall Clips (12) can be used to assist with wire routing.
11. Loosen 4 screws on front of Electrical Box (4) to remove front cover. Insert Battery (9) into Electrical
Box (4) (+ to +).
12. Red LED (45) will light and initial calibration will begin. After about 5 seconds, Red LED (45) turns off
indicating initial calibration is complete. Replace front cover and tighten screws.
Note: Do not touch the faucet during initial calibration. If faucet is touched, remove battery and
return to Step 11.
13. Open water supply and activate faucet so water runs through Spout (13). Check all connections for
leaks.
14. Activate faucet 10 times for final calibration:
a. For DT1, touch Spout (13) to turn on. Remove hand and allow to run for 10 seconds. Touch
again to turn off. Wait 10 seconds before next activation.
b. For DTM2, touch Spout (13) to turn on. Remove hand and allow to run until it turns off
automatically, about 12 seconds. Wait 10 seconds before next activation.
c.
For DP3, move hand near Spout (13) to turn on and leave hand near Spout (13) to allow to
run for 10 seconds. Remove hand to turn off. Wait 10 seconds before next activation.
d.
For DPM4, move hand near Spout (13) to turn on. Remove hand and allow to run until it turns
off automatically, about 12 seconds. Wait 10 seconds before next activation.
Note: Sensor continuously learns environment as it is used. It may take up to a week of regular use to
fully calibrate.
Diagram E – Sensor Connection
Cleaning
1. To clean the spout, press once on White Button (45) to enter cleaning mode for 30 seconds. Red LED
(45) will begin flashing twice repeatedly.
2. During this time, spout may be cleaned without water turning on by touch or proximity.
3. When cleaning mode ends, Red LED (45) will stop flashing and operation will return to normal.
DECK MOUNT AUTOMATIC FAUCET
INSTALLTION FOR
#
Description
4
Electrical Box
7/8
Sensor Washer
13
Spout
42
Solenoid Wire Connector
43
Sensor Wire
44
Solenoid Wire
45
Red LED/White Button
Rev. 9/19