Download Print this page

Watermark AUT-DT1 Installtion Manual page 3

Deck mount automatic faucet

Advertisement

19
Mounting Washer
Note: Refer to Diagrams A, B and D for Steps 4 – 7.
4. Position Solenoid Bracket (3) on the wall so Solenoid Inlet (38) is within 12" of premixed water supply
and Solenoid Outlet (39) is within 12" of Spout Inlet (40 or 41). Secure with 2 Wood Screws (10).
Drywall Anchors (11) may be used if securing to drywall.
5. Slide Solenoid Valve (2) into Solenoid Bracket (3). Solenoid should be oriented with inlet on bottom
and outlet on right.
6. Connect Supply Hose (5) to the premixed water supply and to Solenoid Inlet (38).
7. Connect Spout Assembly (1) to Solenoid Valve (2):
a. For spout Types I & IV, connect Spout Hose (6) to Spout Inlet (40) and to Solenoid Outlet
(39).
b. For Spout Types II, III & V, connect Spout Inlet (41) to Solenoid Outlet (39).
Diagram D – Solenoid Connection
Types I & IV
DECK MOUNT AUTOMATIC FAUCET
28
Tee Washer
Types II, III & V
INSTALLTION FOR
37
Tee
#
Description
1
Spout Assembly
2
Solenoid Valve
5
Supply Hose
6
Spout Hose
38
Solenoid Inlet
39
Solenoid Outlet
40
Spout Inlet (Types I & IV)
41
Spout Inlet (Types II, III & V)
Rev. 9/19
P a g e
| 3