Do you have a question about the KoiMedicPro and is the answer not in the manual?
Questions and answers
Dayal
February 16, 2025
After battery replacement how to calibrate
1 comments:
Mr. Anderson
May 14, 2025
After replacing the batteries in the Trans Instruments Pro, you should perform a calibration using the recommended calibration fluid. Calibration is recommended to ensure accurate measurements and should be done every 6 months or after maintenance activities like battery replacement.
Page 2
measures three most basic parameters for the water management of Koi pond. Salinity – Maintaining correct level of salt in pond water benefits fishes especially koi, here are the benefits: It is safe for pond fish species It does not push sick fish “over the edge.” ...
Page 3
PRODUCT INSTALLATION & DESCRIPTION: Hand Strap Hole Catch: - Insert probe till Latch snaps in place for a secure lock READ Button HOW? Remove Protective Cap, Salinity hold the body with both Display hands and push probe sensor end on a tabletop till latch “click”...
Page 4
SPECIFICATIONS: Temp. Operating Range : 0 to 14pH 0 to 1 0 to 10 0 to 50ºC Display Resolution 0.1pH 0.01% 0.1ppt 0.1ºC Accuracy ±0.2pH ±0.02% ±0.2ppt ±0.5ºC Temperature Compensation Automatic 0 to 50ºC / 32 to 122ºF Operating Temperature 0 to 50ºC / 32 to 122ºF Battery Type 4 x 1.5V AA size battery...
Page 5
CALIBRATION: Calibration should be made periodically where necessary. Always soak the sensor in tap water for about 5 minutes before calibration. CALIBRATING SALINITY CONCENTRATION READINGS: 1. Use the attached standard solution for this calibration, additional solution can be purchased: ORDER CODE STANDARD SOLUTION SS0005S 0.5% / 5.0ppt...
MAKING MEASUREMENT: 1. Due to storage in different environment, the meter should be re- calibrated before use. 2. Always soak the sensor in tap water for about 5 minutes before making measurements or calibration. 3. Dip the sensor area into measuring liquid up to immersion level and press the READ button.
ERROR CODES 1. When appear during measurement or calibration, it means the meter cannot establish a stable reading during calibration. This could mean an expired or defective sensor. Promptly replace with a new Probe. 2. When “- - -” appear on the Salinity concentration display, it means the solution is out of the meter’s measuring range or too concentrated.
SENSOR PROBE REPLACEMENT: 1. This unit comes with a replaceable probe. Keep in mind that the pH sensor will age and degrade over time subject to usage and storage conditions. The sensor has a usage life of about 1year. When the pH reading becomes erratic or fails to be calibrated, the Probe should be replaced.
Page 9
POND TREATMENT (FOR REFERENCE ONLY) What is the ideal salt concentration for the pond? It is recommended to maintain the salt concentration in the range of about 0.13% to 0.25% (1.3 to 2.5 ppt) in the pond. Salt concentrations between 0.3% and 0.5% (3 to 5 ppt) will upset the osmotic balance of some parasites i.e.
What is the amount of salt to add into the pond? For the first time, the addition of 1 to 2 pounds (0.5 to 1kg) of salt per 100 gallons (500Litre) of water should be sufficient. Control Reading: 0.13% to 0.25% 1.3ppt to 2.5ppt To detoxify nitrite and control algae, using 2 to 3 pounds (1 to 1.5kg) per 100 gallons (500Litre) of water is appropriate to reduce the...
Page 11
POND CALCULATION BASICS: 0.1% = 1 ppt = 1 gm of salt in every 1Litre of water 1 kg 1,000 gram 1 Pound (lb) 0.454 Kilogram(kg) 1 gallon (US) 3.785 L 1 gallon (UK) 4.546 L What is the amount of salt to add into the pond after a reading is recorded? Here is an example if the target value of salt level in your pond water is to be 0.25% or 2.5ppt, below are the steps for adjustments:...
LIMITED WARRANTY Trans Instruments (S) Pte. Ltd. warranties the main unit for a period of 18 months and the sensor probe for 12 months or about 700 tests (whichever comes first) from date of purchase against all defects in material and workmanship. This warranty does not apply to the abuse, misused, probe expiry or tampering of the product.
Need help?
Do you have a question about the KoiMedicPro and is the answer not in the manual?
Questions and answers
After battery replacement how to calibrate
After replacing the batteries in the Trans Instruments Pro, you should perform a calibration using the recommended calibration fluid. Calibration is recommended to ensure accurate measurements and should be done every 6 months or after maintenance activities like battery replacement.
This answer is automatically generated