Heat&Glo ST-550TM-IPI Owner's Manual

Heat&Glo ST-550TM-IPI Owner's Manual

Installation and operation
Table of Contents

Advertisement

Quick Links

Models:
ST-550TM-IPI
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com/translations.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
HOT GLASS WILL
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
CAUSE BURNS.
UNTIL COOLED.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST-550TM-IPI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heat&Glo ST-550TM-IPI

  • Page 1 Pour demander un exemplaire en français de ce Manuel du propriétaire, visitez www.heatnglo.com/translations. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 2: Congratulations

    BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 3: Table Of Contents

    E. Junction Box Installation......43 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 4 D. Contact Information ......62  = Contains updated information. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 9: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 10: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 11: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 12: After Fireplace Is Lit

    Noise is caused by metal expanding and contracting as it heats up and cools down, similar to Metallic noise the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the fi replace. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Remove all foreign objects. • Verify weather stripping, sealing and fl ashing remains intact. • Verify unobstructed air circulation. • Inspect draft shield to verify it is not damaged or missing. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 15 • Verify that there is not a short in fl ame sense circuit by checking continuity between pilot hood and fl ame sense rod. Replace pilot as necessary. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 16: Installer Guide

    VENT PIPE (SECTION 8 and 10) FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) CEILING FIRESTOP ON FLOOR OF ATTIC (SECTION 8.C) GAS LINE (SECTION 11.C) OPTIONAL WALL SWITCH Figure 4.1 Typical System Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 17: Design And Installation Considerations

    Electric drill and bits (1/4 in.) Plumb line Safety glasses Level Reciprocating saw Manometer Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 18: Framing And Clearances

    36 in. 914 mm 36 in. 914 mm Figure 5.1 Appliance Locations Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 19: Constructing The Appliance Chase

    * Adjust framing dimensions for interior sheathing (such as sheetrock) ** NOTICE: Appliance must be raised a minimum of 1/2 inch when using the Modern Front. Figure 5.2 Clearances to Combustibles ST-550TM-IPI Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 20: Mantel And Wall Projections And Non Combustible Zone

    MIN. MEASUREMENT FROM FIREPLACE OPENING TO BOTTOM OF APPLIANCE = 30-1/4 IN. AIR SPACE REQUIRED Figure 5.4 Minimum Vertical and Maximum Horizontal Dimensions of Non-Combustibles Figure 5.6 Non-Combustible Zone Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 21: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 22 2 sides beneath the fl oor. venting system does not meet these requirements. • Vinyl protection kits are suggested for use with vinyl siding. Figure 6.3 Minimum Clearances for Termination Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 23: Continue Adding Vent Components

    (2) sheet metal screws. C. Install Support Brackets Refer to cinch pipe and termination cap installation in- structions. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 24: Vent Information And Diagrams

    SLP48 1219 Length SLP6A 2 - 6 51 - 152 SLP12A 2 - 12 51 - 305 SLP-FLEX-2 SLP-FLEX-3 SLP-FLEX-5 1524 SLP-FLEX-10 3048 Figure 7.2 SLP Pipe Effective Length Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 25: Use Of Flex Vent

    However, the vent attachment point and the fi restop loca- 1 in. CLEARANCE tion are considered to be supports. Figure 7.3 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 26: Vent Diagrams

    • When using any other cap, a section of vertical pipe (12 inches simple up and out installation minimum) MUST be installed prior to attaching a 90° elbow. (see Figure 7.3). Figure 7.4 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 27 fi rst elbow. • When using any other cap, a section of vertical pipe (12 inches minimum) MUST be installed prior to attaching a 90° elbow. Figure 7.5 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 28 fi rst elbow. • When using any other cap, a section of vertical pipe (12 inches minimum) MUST be installed prior to attaching a 90° elbow. Figure 7.6 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 29 fl ame height. If the vent confi guration has a total vertical of 15-50 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 30 Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). INSTALLED HORIZONTALLY Figure 7.10 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 31: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 32: Install The Ceiling Firestop

    Figure 8.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 33: Appliance Preparation

    Be sure to maintain all clearances to combustible material. 90º Figure 9.2 Proper Positioning and Leveling of an Appliance Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 34: Installing Vent Pipe

    Use care when removing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent may leak. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 35: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner fl ue is not required. Figure 10.6 Securing Horizontal Pipe Sections • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 36: Disassemble Vent Sections

    1/8 in. (3 mm) larger than the support box outline. • Lower the support box through the hole in the roof until its bottom is at least 2 in. (51 mm) below the ceiling (Figure 10.9). Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 37: Install Metal Roof Flashing

    • Caulk the overlap seam of any exposed pipe sections • Caulk around the top of the storm collar. See Figure 10.15. that are located above the roof line. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 38: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.16. Figure 10.16 Wall Thimble Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 39: Install Horizontal Termination Cap

    fl ashing kit and HRC caps are available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 40: Gas Information

    fl exible gas connector are connected to the 1/2 inch (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 41: Electrical Information

    Battery polarity must be correct or module damage will occur. When using batteries, place the battery pack outside the decorative front to prolong the life of the batteries. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 42 TRANSFORMER ORANGE 3 VAC WHITE GROUND TO FIREPLACE PLUG IN CHASSIS WIRES BATTERY PACK (TO BROWN) REMOTE PLUG IN VALVE Figure 12.2 IntelliFire Ignition Wiring Diagram with Remote Receiver Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 43: Junction Box Installation

    NOTICE: DO NOT wire 110 VAC to wall switch. previously removed. Ensure that a Romex connector is used to attach the electrical wires to the junction box. Figure 12.4 Junction Box Detail Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 44: Finishing

    TOP SLOT Figure 13.2 Step 3. Crease fl aps on left and right sides of splatter guard Figure 13.5 using the scored line as the guide. See Figure 13.8. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 45 Carefully grab splatter guard on or near the vertical center on the left and right sides. Pull outward gently, but fi rmly, Figure 13.8 taking care not to tear or remove the inserted tabs. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 46: Mantel And Wall Projections

    MIN. MEASUREMENT FROM FIREPLACE OPENING TO BOTTOM OF APPLIANCE = 30-1/4 IN. Figure 13.13 Minimum Vertical and Maximum Horizontal Dimensions of Non-Combustibles AIR SPACE REQUIRED Figure 13.15 Non-Combustible Zone Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 47: Facing Material

    = COMBUSTIBLE MATERIAL 9 in. 0 in. 0 in. High Temperature Sealant (300° F/149° C min.) Top and Side Seal Joint Figure 13.16 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 48 FINISHING MATERIAL FINISHING MATERIAL (TOP EDGE) 4 IN. MAXIMUM THICKNESS 4 IN. MAXIMUM THICKNESS 34-1/2 IN. 37-1/4 IN. Figure 13.17 Modern Door Overlap Fit Figure 13.18 Modern Door Inside Fit Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 49: Appliance Setup

    Figure 14.1. The rock placement jig is located in the base of the unit. Figure 14.4 Burner Slot Free of Glass Rock Media Figure 14.1 Rock Placement Jig Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 50: Fixed Glass Assembly

    • Pull out and latch the two glass assembly latches into the groove on the glass frame. • Make sure both sides are replaced properly. GLASS ASSEMBLY LATCHES (BOTH BOTTOM AND TOP) Figure 14.5 Fixed Glass Assembly Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 51: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 52 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 53: Reference Materials

    GAS LINE ACCESS LEFT VIEW FRONT VIEW RIGHT VIEW Location Inches Millimeters Location Inches Millimeters 4-1/4 31-1/8 1-1/2 37-5/8 8-3/4 30-1/4 41-1/4 1048 2-1/8 31-1/4 3-7/8 Figure 16.1 See-Through Dimensions Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 54 MODERN-32 DECORATIVE FRONTS 26-15/16 37-1/8 9-1/2 34-7/16 ST-550TM-IPI Figure 16.2 Modern-32 Decorative Front Dimensions Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 55: Vent Components Diagrams

    (610 mm) SLP-FLEX-5 1524 SLP-FLEX-10 3048 DVP-HSM-B Extended Heat Shield DVP-AS (Attic Shield) SLP-HVS SLP-WS SLP-FS Horizontal Pipe Wall Shield Firestop Ceiling Firestop Support Figure 16.3 SLP Series Vent Components Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 56 Wall Thimble-Black Termination Cap Support Box-Black Black SL-2DVP SLP-TVHW DVP-2SL Adapter Vertical Adapter Termination Cap DVP-FBHT DVP-FBHT SL-2DVP SLP90 SLP-FLEX-TRAP Horizontal Termination Kit ASSEMBLY Figure 16.4 SLP Series Vent Components Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 57 HORIZONTAL TERMINATION CAP 7-3/8 IN. 187 mm 17-7/8 IN. 454 mm 14 IN. 356 mm 12 IN. 305 mm SLP-TB1 Basement Vent Cap Figure 16.5 SLP Series Vent Components Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 58 9-3/16 IN. (233 mm) 13-5/8 IN. 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. SLP-LPC (318 mm) SLP Low Profi le Cap Figure 16.6 Vent Components Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 59 100 FT PV Wire Harness PVI-WH100 separately. Use if the PVLP-SLP is installed in a high traffi c area. PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 16.7 PVLP-SLP Vent Components Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 60: Service Parts

    Pkg of 2 33858/2 Pilot Bracket 2142-124 Surround Overlay (contains overlay for top, bottom and sides) SRV2126-FACE Touch Up Paint TUP-GBK-12 Additional service part numbers appear on following page. 12/15 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 61: Service Parts

    Ori ce LP (#54C) 582-854 Conversion Kit NG NGK-550TM Conversion Kit LP LPK-550TM Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Regulator NG NGK-DXV Regulator LP LPK-DXF Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...
  • Page 62: Contact Information

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2015 Heat & Glo • ST-550TM-IPI • 2142-900 Rev. P • 12/15...

Table of Contents