80/104
Bosch Rexroth AG
Help in case of faults
11 Help in case of faults
This chapter summarizes information which may help you should any faults
occur on the WS290 training system.
Table 10: Faults
Situation
Electric motor switched on
by means of "ON" switch
but the motor does not
start up.
Electric motor switched on
by means of "ON" switch
but no flow can
be identified.
There is permanently foam
in the measuring glass.
If it is not possible to identify and remedy fault causes, please contact the
responsible Bosch Rexroth service department.
Hydraulics training system WS290 | RE 00225-B/2.15
Possible causes
Recommended remedy
Hydraulic power unit at
Operate the
the electric control box
OFF pushbutton
not connected.
Establish the
cable connection
Repeat the switch-on
Automatic circuit breaker
Do not repeat the switch-on
has been triggered
Commission a qualified,
EMERGENCY OFF
specialized electrician with
pushbutton is operated
the examination and remedy
Filling level in the tank is
Immediately stop the
too low
hydraulic power unit
Refill hydraulic fluid
Wrong direction of rotation
Immediately stop the
of the motor
hydraulic power unit
Commission a qualified,
specialized electrician with
the examination and remedy
Coupling damage between
Immediately stop the
electric motor and pump
hydraulic power unit
Commission a qualified,
specialized electrician with
the examination and remedy
Leakage in the suction
Immediately stop the
range
hydraulic power unit
Inform the Bosch Rexroth
service