Trouble Shooting - Water Depot Blaster Soft Owner's Manual

Table of Contents

Advertisement

Problem
Sulphur coming through
Iron coming through
Unit regenerating in
afternoon
Not removing sulphur or
iron
Most service should be around the following:
1) Ozone is working
2) Brine draw is working...sucking
3) Board is set right
4) Increase the ozone draw, backwash etc.
5) Check chemistry of water
6) PH should be 6.8 or higher
7) Obstruction in drain line
8) Did not install the back flow check valve
9) Setting for ozone to come properly programmed
10) By Pass is not open
11) Too much iron or sulphur for unit
Error board flashing see manual for setting.

Trouble Shooting

Follow up
Check the amount of sulphur you
are trying to remove...it may be
too much to remove or low PH
Same as above, ph of 6.8 or lower
may require a ph filter
Settings are incorrect
Listen to back wash
Overview
Action
Set to everyday regeneration, 60 min
draw
Same as above
Go to unit set for 2 am setting
1) Check for obstruction in
backwash, Check flow
restrictor, Regenerate more
often
2) Check the ozone generator
is working
3) Clean the ozone tube
28