    Frequently Asked Questions..................... Dear customer, Thank you for choosing the LTR 100 NEO from Comedes GmbH. You have purchased a powerful dehumidifier developed to the latest technical standards. To ensure that the device will remain your faithful servant over a long period of time, we ask you to study the operating instructions, in particular the safety instructions, in detail.
  • Page 3 WARNING: Read the instructions carefully before commissioning. Failure to follow the safety instructions and instructions may result in electric shock, fire and/or serious injury. Keep all safety instructions and instructions for the future. Watch your step! Do not open the device until the mains plug has been disconnected from the mains socket.
  • Page 4: Safety Instructions

    safety instructions manufacturer, its service representative, or similar Do not use any means other qualified personnel to avoid than those recommended by hazards. the manufacturer to speed up Please contact a specialist to the defrosting process or to have the product repaired. clean the dehumidifier.
  • Page 5 understand the resulting Do not clean the dehumidifier hazards. Children are not with water or chemicals. allowed to play with the Prevent water from getting device. Cleaning and on/to the unit. maintenance must not be Do not spray the unit with carried out by children flammable liquids or cleaning without supervision.
  • Page 6 Do not operate the disposal dehumidifier via a multiple When transporting equipment socket, a plug adapter or an and parts containing extension cable. flammable refrigerants, the Do not operate the equipment transport regulations must be if it has been dropped, observed.
  • Page 7: Intended Use

    If propane gas is present or are therefore non-flammable suspected to be present, do and spark-free. Components not let untrained persons may only be replaced by search for the cause. identical spare parts approved The propane gas used in this by the manufacturer.
  • Page 8: Technical Data

    Technical data Product name: Comedes LTR 100 NEO Tension: AC220-240V/50 Hz Nominal power: 170W (30°C 80% humidity) Power consumption: 1,1 A (30°C 80% humidity) Dehumidification capacity: 12 l/ day (30°C 80% humidity) Weight: 10,5 kg Permissible operating temperature: 5-35°C Coolant / Quantity:...
  • Page 9: Installation Instructions

    Figure 3: Display automatic mode Tank "full" power indicator fan speed timer Blue: Small fan stage Orange: Large fan stage continuous display operation Display: The illuminated display shows the prevailing room humidity as soon as the unit is plugged in. During the setting of the timer and the target air humidity, the selected values are displayed.
  • Page 10: Before Commissioning

    There would be a risk of compressor damage. After switching off, leave the Comedes LTR 100 NEO to stand for at least 3 minutes without moving the appliance so that the water in the drip tray can drain off completely.
  • Page 11 This LED lights up blue for the small fan stage and orange for the high fan stage. Empty water tank: After the water tank is full, the Comedes LTR 100 NEO automatically switches off and the tank "Full" indicator (Fig. 3) lights up. This is also indicated acoustically.
  • Page 12: Hose Drainage

    The Comedes LTR 100 NEO can also be operated with a drainage hose (Ø9.0mm). To do this, remove the water tank and attach a drainage hose.
  • Page 13: Recommendations For Drying With The Comedes Ltr 100 Neo

    At a room temperature between 13°C and 20°C, the unit starts defrosting every 45 minutes. Recommendations for drying with the Comedes LTR 100 NEO In order to achieve the best possible dehumidification result with the LTR 100 NEO with the lowest possible energy input, we provide the following information: Since this manual can only provide limited help, we recommend that you visit www.
  • Page 14 In the case of construction defects and water damage, the cause should first be eliminated. The rooms can then be dried with condensation dryers such as the LTR 100 NEO. The dehumidifier is operated in continuous operation. The ambient temperature should be at least 20°C (not more than 27°C).
  • Page 15 The diagram assumes that temperatures >=20°C are residential rooms and temperatures <=20°C are basement rooms.
  • Page 16 Always turn off the power and unplug the appliance before cleaning, servicing or repairing it. A maintenance log must be kept for the operation of the device as follows Maintenance log for Comedes LTR 100 NEO: Serial number: …………………………………. Maintenance and...
  • Page 17 Maintenance intervals: in front of Maintenance and everyone With At least all At least all At least all At least care interval commis- need 2 weeks 4 weeks 6 months annually sioning Check air inlet and outlet and remove im- purities.
  • Page 18: Frequently Asked Questions

    6. if the above points are ok, try again in 10 minutes. 7. is the timer function activated? 8. if the device is still not working, please contact service@comedes.com The dehumidification performance is too low. 1. is the dust filter dirty? 2.