Pentair HI FLOW SIX-WAY 1-1/2 INCH TOP MOUNT VALVE Installation And User Manual

Pentair HI FLOW SIX-WAY 1-1/2 INCH TOP MOUNT VALVE Installation And User Manual

Advertisement

Quick Links

HI FLOW
SIX-WAY 1-1/2 INCH TOP MOUNT VALVE
INSTALLATION AND USER'S GUIDE

Table of Contents

Operation ..........................................................................
Installation ........................................................................
Maintenance .....................................................................
Troubleshooting ...............................................................
Replacement Parts ...........................................................
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
Valve Care ...............................................................
Winterizing ...............................................................
SAVE THESE INSTRUCTIONS
2
2
2
4
4
4
4
5
6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HI FLOW SIX-WAY 1-1/2 INCH TOP MOUNT VALVE and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair HI FLOW SIX-WAY 1-1/2 INCH TOP MOUNT VALVE

  • Page 1: Table Of Contents

    HI FLOW ™ SIX-WAY 1-1/2 INCH TOP MOUNT VALVE INSTALLATION AND USER’S GUIDE Table of Contents Operation ................Valve Positions Installation ................ Maintenance ..............Replacing the Valve Top and Diverter Assembly ..Valve Care ............... Winterizing ............... Troubleshooting ............... Replacement Parts ............IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...
  • Page 2: Operation

    OPERATION INSTALLATION The filter valve will be installed on to the filter in one of two Air entering a filter with a poorly or improperly ways depending upon the filter and valve type: closed valve clamp can cause the valve to separate from the filter and can cause severe bodily injury and/or •...
  • Page 3 9. Lift the clamp (item 14) over the tank flange and 15. Orient the filter and valve to allow the ports to be carefully guide the clamp so that it catches both the plumbed to the proper location. valve flange and the tank flange as shown in Figure 1. 16.
  • Page 4: Maintenance

    MAINTENANCE Replacing the Valve Top and Diverter Valve Care Assembly The valve is a very important part of your pool equipment and system. Proper care and maintenance will add many 1. Shut off pump and open air bleeder to relieve all years of service and enjoyment to the pool.
  • Page 5: Troubleshooting

    TROUBLESHOOTING Problem Possible Cause Corrective Action Leak to Waste Port Dirt or sand under seal. Remove valve top and clean seal area. Damaged seal. Replace valve top assembly. Damaged valve body in seal area. Replace valve body. Leakage at Port Cracked ports.
  • Page 6: Replacement Parts

    REPLACEMENT PARTS Item # Part # Description 272520 Handle 272505 Washer, Plastic (Qty2) 272405 Screw, Handle 272527 Valve Top, Black 272511 O-Ring, Diverter Shaft 354053 O-Ring 272401 Washer, SS 272400 Spring, 100lb. 1-13/16 O.D. SS 272535 Spring, 100lb. 1-3/8 O.D. SS 272512 Diverter w/Grasket Screw, #10-24 Hex Pan HD...
  • Page 7 NOTES HI FLOW™ Six-Way 1-1/2 Inch Top Mount Valve Installation and User’s Guide...
  • Page 8 Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties.