Switch Dio - Ebyte TLSR8253F512 Serias User Manual

Patch sig mesh group module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
2. Transparent transmission of information
E104-BT12 supports transparent transmission of user data. The maximum length of the serial port sub-packet is 60 bytes
(the maximum payload of a single packet in the bottom layer of the mesh is 8 bytes, and data larger than 8 bytes will be
automatically sub-packed and sent, due to the efficiency of the entire mesh network during the sub-packet sending
process. Not high, it is recommended to limit the data sent in a single time to less than 8 bytes), the data format is as
follows:
Send
Order(1byte)
0xC2
Receive
Order(1byte)
0x42
For example: Device 0001 sends the hexadecimal data of "00112233445566778899" to device 0004
Sender
Receiver

5. Switch DIO

E104-BT12 switches for furniture-only applications. Each module of our E104-BT12 supports two elements. There are
many modules under one element. The reference model is shown below.
E104-BT12
Element one
Support a lot of MODLE
Switch DIO1 bound element one
Element two
Only supports onoff modle and
level modle
Switch DIO2 bound element two
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Respond
08 41 0004 0001 8204 00
Target address (2 bytes)
Primary address of Target
device
Target address (2 bytes)
Primary address of Target
device
0D C2 0004 00112233445566778899
0F 42 0004 0001 00112233445566778899
Data
Valid data
Original
address
(2
Data
bytes)
Source device master
Valid data
address
E104-BT12LSP User Manual
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

E104-bt12lsp