Ebyte TLSR8253F512 Serias User Manual page 19

Patch sig mesh group module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Note:Default 10000
This instruction be for E104-BT12SP-L configuration operation only
TIME:16-cimal segment mode
Column: Set 5000 ms, convert 5000 to 16-digit value 1388. When you set it, you need to write
8813.
04 C0 0F 8813
4.2.1.17 Reading LPN Unstructured Networks to Sleep Time
Operation
al code
Request
0x10
Respond
0x10
Request:04 C0 10
Example
Respond:05 40 10 TIME
Note:
This instruction be for E104-BT12SP-L configuration operation only
TIME:16-cimal segment mode
Column: If the reading value is 8813, 8813 is small-end mode, the actual value is 1388,
converted to decimal value is 5000
4.2.2 SIG Messages
The E104-BT12 module supports SIG Generic and Lighting HSL model control (see Mesh Profile and Mesh Model
introduction for relevant SIG message definitions).The SIG message format is as follows:
Send
Order(1byte)
0xC1
Receive
Order(1byte)
0x41
For example: 1.Generic onoff control of Generic model:
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Parameter
None
Set time-out sleepout.
Target address (2 bytes)
Primary address of Target
device
Target address (2 bytes)
Primary address of Target
device
Control the device whose main address is 0004, output
high level without delay
Request
09 C1 0004 8202 01000000
Respond
08 41 0004 0001 8204 01
Control the device whose main address is 0004, output low
level without delay
Request
09 C1 0004 8202 00000000
Sig mesh message
Request
Original
address
(2
Sig mesh message
bytes)
Source device master
Respond
address
E104-BT12LSP User Manual
19