Ebyte TLSR8253F512 Serias User Manual page 13

Patch sig mesh group module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
4.2.1 Parameter Configuration
Configuration data is used for reading and writing module parameter information and for device access operations
in the following format:
Send
Receive
Instructions: Proper configuration operation gives corresponding response data. If the configuration error returns the
error code, the following:
4.2.1.1 Get the current network address and status of the device
Network keys are used for network IDs assigned by provisers during network formation in the following format.
Operation
al code
Request
0x00
Respond
0x40
Request:02 C0 00
Example
Respond:06 40 00 DATA[3]
Description:
This instruction is only applicable to E104-BT12SP-L, E104-BT12SP-N to obtain network
addresses and configure networks
DATA analysis
Unorganized network:
DATA[0] =0x00,DATA[2],DATA[3]0
Network :
DATA[0] =0x01,DATA[2],DATA [3] is the module network address.
4.2.1.2 Baud Settings
Operational code
Request
0x01
Respond
0x01
Order
Example
03 C0 01 xx
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Directive(1 byte)
Operational code ( 1
byte)
0xC0
0~255
0x40
0~255
Error code
Explanation
0x0D
invalid parameter
0x0E
Parameter length error
0x0F
error instruction
Parameter
06 40 00 data
Parameter
Baud rate serial number to be set (range 0x00~0x07)
Returns the current baud rate serial number.
Baud rate specification
Xx represents the baud rate label to be set(0x00~0x07)
00:230400
E104-BT12LSP User Manual
Data(N byte)
Request data
Response data