Patch sig mesh group module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Column: Reading values 8813, 8813 is small-end mode. Actual value is 1388, converted to
decimal value of 5000
4.2.1.14 Setting up LPN polling friend time
Operation
al code
Request
0x0D
Respond
0x0D
Request:04 C0 0D TIME
Example
Respond:05 40 0D TIME
Note:Default 2000
This instruction be for E104-BT12SP-L configuration operation only
TIME:16-cimal segment mode
Column: Set 5000 ms, convert 5000 to 16-digit value 1388. When you set it, you need to write
8813.
04 C0 0D 8813
4.2.1.15 Reading LPN polling friend time
Operation
al code
Request
0x0E
Respond
0x0E
Request:04 C0 0E
Example
Respond:05 40 0E TIME
Note:
This instruction be for E104-BT12SP-L configuration operation only
TIME:16-cimal segment mode
Column: If the reading value is 8813, 8813 is small-end mode, the actual value is 1388,
converted to decimal value is 5000
4.2.1.16 Set LPN to Sleep Time without Networking
Operation
al code
Request
0x0F
Respond
0x0F
Request:04 C0 0F TIME
Example
Respond:05 40 0F TIME
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Parameter
None
Set time-out sleepout.
Parameter
None
Set time-out sleepout.
Parameter
None
Set time-out sleepout.