Fuse Protection - Beckhoff AX2090-BW65 Assembly Instructions Manual

External ip 65 braking resistors
Table of Contents

Advertisement

Operating ranges
8.3.1

Fuse protection

8.4
Version: 1.0
The following table provides information on the development of
overtemperature with continuous power:
Operating range Explanation
Normal:
Recommended operating range for maximum
Maximum 130 %
lifetime with error-free operation
Permissible:
Still permissible operation with short service life
Maximum 160 %
and high failure probability
Impermissible:
Risk of destruction of the brake resistor due to
Over 160%
overheating and endangerment of the surround-
ing components due to high temperature
Line protection requirements
Line protection is implemented electronically internally. It requires
activation of the thermal model for the selected resistor, and the
correct braking resistor cable must be used.
The system may be damaged if this is ignored.
AX2090-BW65
Electrical installation
───
31

Advertisement

Table of Contents
loading

Table of Contents