Cn - Suppression Of No Reads - AEG ARE DT1 Installation Manual

Table of Contents

Advertisement

Sequence of reading cycles
N, N, ......,N, A, A, A, ....A, N,N,
.........
N. N, N, A, A, A, N, A, A, B, A,
C, C, C, .......
The settings are directly effective.
Note: The internal reference number is deleted in the following conditions:
after a cold start
after a warm start (command line RST <CR>)
after entering the command line CID <SP> 1 <CR>
This causes that the next transponder code is output definitely.
Note: The filter function CID picks up the results of the complete reading cycles! The filter function
CID has effect on the serial interface only.
3.3.3 CN – suppression of No Reads
Through the setting CN=1 the NoRead results after a get tag command or in MD0 mode are sup-
pressed on the serial interface.
Input format:
Output (example):
Parameter:
PARAMETER
0
1
--------------------------------------------------------------------------------17/45--------------------------------------------------------------------------------
Output sequence
after filtering with
CN=0 und CID=1
N, N, ......,N, A, N,
N, .......
N. N, N, A, N, B,
A, C, .....
CN <SP> parameter <CR>
0 <CR>
FUNCTION
No suppression
Suppression of equal transponder numbers
Output sequence
after filtering with
CN=1 und CID=1
A
A, B, A, C

Advertisement

Table of Contents
loading

Table of Contents