Summary of Contents for Wanner Engineering STAN-COR

  • Page 1 Installation and Operation Manual SCK-991-2400B Solid Kynar, Non-Metallic ANSI Centrifugal Pumps W0439 WANNER ENGINEERING, INC. 1204 Chestnut Avenue, Minneapolis, MN 55403 TEL: (612) 332- 5681 FA X: (612) 332- 6937 TOLL-FREE FAX [US only]: (800) 332-6812 www.stancorpump.com email: sales@wannereng.com...
  • Page 2: Table Of Contents

    If you have questions, or General Instructions ..........2 if there are problems at start-up, contact the Stan-Cor Pump Distributor in your area. Installation ............3 The fluid end of the Stan-Cor Pump is solid, carbon-filled Operation ..............
  • Page 3: Installation

    The base plate should be installed in a level position. The size and location of the base mounting holes are shown on the certified Concrete Stan-Cor Dimension Drawing. For a general piping layout, use Foundation the dimensions shown on the back page.
  • Page 4 1”: 10-15 ft-lbs 1-1/2”: 10-15 ft-lbs 2”: 20-25 ft-lbs 3”: 25-30 ft-lbs 4”: 30-35 ft-lbs W0443 Sample Style “A” Sample Style “B” Fig. 4: Expansion Joints United States Instant Information: www.wannereng.com Wanner Engineering, Inc. (61) 33-5681 Fax (61) 33-6937 SCK-991-400B...
  • Page 5: Operation

    If flow is lost, close the discharge valve and wait a few seconds for the discharge pressure to rebuild. Temperature (F) W0446 United States Instant Information: www.wannereng.com Wanner Engineering, Inc. (61) 33-5681 Fax (61) 33-6937 SCK-991-400B...
  • Page 6: Service

    Note: An impeller removing wrench can be easily made by welding two steel bars to an old coupling hub. United States Instant Information: www.wannereng.com Wanner Engineering, Inc. (61) 33-5681 Fax (61) 33-6937 SCK-991-400B...
  • Page 7 (grease on outside of seal and inside of housing). Press the to step 21. oil seal into the bearing housing (15) until it is flush with the outboard surface. United States Instant Information: www.wannereng.com Wanner Engineering, Inc. (61) 33-5681 Fax (61) 33-6937 SCK-991-400B...
  • Page 8 Double Mechanical Seal. The seal length is preset by the stuffing box, and only the set screws need to be tightened. Use an Allen wrench through the flush tap. United States Instant Information: www.wannereng.com Wanner Engineering, Inc. (61) 33-5681 Fax (61) 33-6937 SCK-991-400B...
  • Page 9: Parts

    37 Screw, hex-head cap 38 Screw, hex-head cap 39 Screw, hex-head cap 40 Nut, hex 41 Nut, hex 42 Screw, socket-head 43 Screw, socket-head • Not Illustrated United States Instant Information: www.wannereng.com Wanner Engineering, Inc. (61) 33-5681 Fax (61) 33-6937 SCK-991-400B...
  • Page 10: Troubleshooting

    — Insufficient discharge head (excessive flow) — — Improper lubricant or level — — — — — — Impeller clearance too large — — — — United States Instant Information: www.wannereng.com Wanner Engineering, Inc. (61) 33-5681 Fax (61) 33-6937 SCK-991-400B...
  • Page 11 Troubleshooting Note: The troubleshooting of mechanical seals is ordinarily Leakage Behind Rotating Face Or At Clamp Ring left to the seal manufacturer. However, the fact that Stan-Cor Of Mechanical Seal pumps are nonmetallic presents some possible problems that Mechanical Defects. Check the rotating member of the are particularly germane to plastic pumps.
  • Page 12 Wanner Engineering, Inc. Wanner Engineering, Inc. will repair or replace, at its option, defective parts without charge if such parts are returned with transportation charges prepaid to Wanner Engineering, Inc., 1204 Chestnut Avenue, Minneapolis,...