REMOVING THE ACTIVEPURE® CELLS
WARNING:
• Unplug the unit before performing any maintenance procedures
• Do not operate the Aerus Pure & Clean without the Filter Assembly and Back Cover properly installed
CAUTION: Do not look directly at the glowing lamp. Prolonged exposure, even to reflected UV light, can cause eye damage according
to the American Conference of Governmental Industrial Hygienists (ACGIH) Standards.
NOTE: Use genuine Aerus replacement parts only. Parts from anyone other than Aerus may damage your unit and void your warranty.
1. Unlock the ActivePure®
Cell connector by pressing
on the connector's locking
tabs.
INSTALLING THE ACTIVEPURE® CELLS
WARNING:
• Unplug the unit before performing any maintenance procedures
• Do not operate the Aerus Pure & Clean without the Filter Assembly and Back Cover properly installed
1. Slide the ActivePure® Cell
up and into the unit. Be
sure the back lip of the
ActivePure® Cell engages
the two slotted protrusions
at the rear of the unit, and
that the angle brackets and
studs are correctly aligned.
4. Replace the Filter
Assembly, inserting
the bottom of the
Filter Assembly first.
10
2. Pull the connector
straight out to unplug.
3. Remove two (2)
thumbscrews.
2. Insert the two
thumbscrews and
tighten. Insert the
ActivePure® Cell
connector into the plug
at the rear of the unit.
5. Replace the Back
Cover by inserting
the bottom in and
snapping into
place.
4. Slide the
ActivePure® Cell
down and out
of unit.
3. Press the connector
firmly until the two
tabs lock into place.