O P E R A T I N G M A N U A L
AC Standard Motors
Induction Motor
Introduction
Before use
Only qualified personnel should work with the product.
Use the product correctly after thoroughly reading the section
"Safety precautions".
Should you require the inspection or repair of internal parts, contact
the Oriental Motor office where you purchased the product.
The product described in this manual has been designed and
manufactured for use as an internal component for general industrial
equipment, and must not be used for any other purpose. Oriental
Motor Co., Ltd. is not responsible for any damage caused through
failure to observe this warning.
Standard and CE Marking
Motors are recognized by UL. Recognized name are motor model
name. Voluntary display of the CE mark conforming to the Low
Voltage Directives.
Standards
UL 1004-1, UL 1004-3, CSA C22.2 No.100, CSA C22.2 No.77
Standards File No.
UL File No.E64197
Applications for standard
EN 60034-1, EN 60034-5, EN 60664-1
A Running Heating Test and a Locked-Rotor Test has been
conducted with a aluminum radiation plate of size indicated below.
For the motor with a gearhead, tests has been conducted with a
gearhead instead of the radiation plate.
First number in
Size
motor name
[mm (in.)]
135 × 135
4
(5.31 × 5.31)
165 × 165
5 (40 W)
(6.50 × 6.50)
200 × 200
5 (60 W, 90 W)
(7.87 × 7.87)
Installation conditions
Overvoltage category II, Pollution degree 3 (except for the motor
mounting surfase and conduit opening), Class I equipment (For EN
standards)
When the machinery to which the motor is mounted requires
overvoltage category III specifications, connect to power supply via
an isolation transformer.
RoHS Directive
The products do not contain the substances exceeding the restriction
values of RoHS Directive (2011/65/EU).
∗ 5IK60GU-FCH, 5IK60GU-ECH, 5IK60GU-SH, 5IK90GU-FCH,
5IK90GU-ECH and 5IK90GU-SH do not comply with the hazardous
substances.
HM-9264-4
Conduit Box Type
Thickness
Material
[mm (in.)]
5
Aluminium
(0.20)
Thank you for purchasing an Oriental Motor product.
This Operating Manual describes product handling procedures and
safety precautions.
• Please read it thoroughly to ensure safe operation.
• Always keep the manual where it is readily available.
Safety precautions
The precautions described below are intended to prevent danger or
injury to the user and other personnel through safe, correct use of the
product. Use the product only after carefully reading and fully
understanding these instructions.
Handling the product without observing the
Warning
instructions that accompany a "Warning" symbol
may result in serious injury or death.
Handling the product without observing the
Caution
instructions that accompany a "Caution" symbol
may result in injury or property damage.
The items under this heading contain important
Note
Note
handling instructions that the user should observe to
ensure safe use of the product.
• Do not use the product in explosive or corrosive environments, in
the presence of flammable gases, locations subjected to splashing
water, or near combustibles. Doing so may result in fire, electric
shock or injury.
• Assign qualified personnel the task of installing, wiring,
operating/controlling, inspecting and troubleshooting the product.
Failure to do so may result in fire, electric shock or injury.
• Do not transport, install the product, perform connections or
inspections when the power is on. Always turn the power off
before carrying out these operations. Failure to do so may result in
electric shock.
• Turn off the power in the event the overheat protection device
(thermal protector) is triggered. Failure to do so may result in
injury or damage to equipment, since the motor will start abruptly
when the overheat protection device (thermal protector) is
automatically reset.
• The motor is class I equipment. Install the motor so as to avoid
contact with hands, or ground it to prevent the risk of electric
shock.
• Install the motor in an enclosure in order to prevent electric shock
or injury.
• Keep the input power voltage within the specification to avoid fire
and electric shock.
• Connect the cables securely according to the wiring diagram in
order to prevent fire and electric shock.
• Do not forcibly bend, pull or pinch the lead wires. Doing so may
result in fire and electric shock.
• Turn off the power in the event of a power failure, or the motor
will suddenly start when the power is restored and may cause
injury or damage to equipment.
• Do not touch the connection terminal of the capacitor immediately
after the power is turned off (for a period of 30 seconds). The
residual voltage may cause electric shock.
• Do not disassemble or modify the motor. This may cause electric
shock or injury.
Warning
1

Advertisement

loading

Summary of Contents for Oriental motor 4IK25GN-FCH

  • Page 1 Should you require the inspection or repair of internal parts, contact Warning instructions that accompany a “Warning” symbol the Oriental Motor office where you purchased the product. may result in serious injury or death. The product described in this manual has been designed and...
  • Page 2 • OPERATING MANUAL ....1 copy Motor Checking the model name Check the model number against the number indicated on the product. Mounting screw (not provided) Model Model Model 4IK25GN-FCH 4IK25GN-ECH 4IK25GN-SH 4IK25AA-FCH 4IK25AA-ECH 4IK25AA-SH Mounting plate 5IK40GN-FCH 5IK40GN-ECH 5IK40GN-SH...
  • Page 3 Connection method to a terminal box • Pinion shaft type • Open the terminal box and connect wires. Drill holes on the mounting plate and fix the motor and gearhead on • Use applicable cable ground and conduit for conduit opening. the plate using screws supplied with the gearhead.
  • Page 4 • If terminal blocks or crimp terminals are • Oriental Motor shall not be liable whatsoever for any problems used, check them for poor connection. relating to industrial property rights arising from use of any • Keep the load at or below the allowable value.

This manual is also suitable for: