Delta DFS150-485 User Manual page 32

2d fixed scanner
Table of Contents

Advertisement

Appendix
Table 73. Slave ID (0x900B)
Bits
Default Value
7:0
1
Table 74. Scan mode Trigger and Data Type (0x900C)
Address: 0x900C; Default Value: 3 ( Slave Modbus, RTU, Manual Trigger )
The register will be effective after
Bits
Name
7:4
3
TRG
2
DTF
1:0
CMM
Table 75. System reset (0x900D)
Bits
Default Value
7:0
1
Table 76. Uart Setting (0x900E)
Address: 0x900E; Default Value: 0 ( 115200, 8, N, 1 )
The register will be effect after the next reboot.
Bit
Name
7
SBL
6:5
PT
A-14
Access
WR
The Slave ID in slave Modbus mode.
. Refer to
on Chapter 3
Reset
Access
Reserved
0
RW
0
RW
3
RW
Access
This selection erases all your setting and resets the DFS to
WR
the original factory defaults.
Reset
Access
0
RW
0
RW
Description
Description
Trigger Source
0: MANUAL TRIGGER
1: CONTINUOUS TRIGGER
Data Format
0: ASCII FORMAT
1: RTU FORMAT
Communication Mode
0: Reserved
1: MASTER PRIVATE MODE
2: MASTER MODBUS MODE
3: SLAVE MODBUS MODE
Description
Description
Stop Bit Length
0: SHORT STOP BIT (1bit)
1: LONG STOP BIT (2bits)
Parity Type
0: NONE PARITY
1: ODD PARITY
DFS150-485 2D Fixed Scanner User Guide