AEC-AMC2-VDS1 - Installation manual
12 V Mode Variations
Figure 5 12 V mode variations
The 12 V mode can be configured using one or two
rechargeable batteries. For a one-battery installation, refer to
Figure 5 - on the left, and perform the following procedure:
1.
2.
3.
For the two-battery installation, refer to Figure 5 - on the right,
and perform the following procedure:
1.
2.
3.
Bosch Sicherheitssysteme GmbH
Connect B1 to the power supply position labbeled BAT.
Connect B2a (black) to the rechargeable battery's -
terminal, and B2b (red) to the rechargeable battery's +
terminal.
Connectors B3a and B3b remain unused - fix them with the
bracket J.
Connect B1 to the power supply position labbeled BAT.
Connect B2a (black) to the rechargeable battery's -
terminal, and B2b (red) to the rechargeable battery's +
terminal.
Connect B3a (black) to the second rechargeable battery's -
terminal, and B3b (red) to the second rechargeable
battery's + terminal.
F.01U.097.255 | V 3.1 | 2008.12