  • Page 1 NEPTUNE SPACE PREDATOR FULL FACE MASK OWNER’S MANUAL...
  • Page 3 For nearly 70 years, OCEAN REEF has been involved in the underwater diving industry. We have contributed much to this industry, from fins and snorkels to the most modern systems of underwater communication. Through the spirit of intrepid pioneers, brilliant inventors, passionate divers, and dynamic entrepreneurs, OCEAN REEF has been able to turn dreams into reality in the underwater world.
  • Page 4: Table Of Contents

    USE OF CONVENTIONAL REGULATOR 1ST STAGE SL 35TX AIR CIRCULATION EQUALIZATION QUICK STEPS PURGING SERIAL NUMBER MAINTENACE AND CLEANING/STORAGE COMMUNICATION TROUBLESHOOTING Schematic and parts list (Neptune Space Predator) Schematic and parts list (SL 35TX) Warranty NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 5: Warning, Caution, Notes

    A CAUTION indicates any situation or technique that could cause damage to the product, and could subsequently result in injury to the user. A NOTE is used to emphasize important points, tips, and reminders. NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 6: Introduction

    This mask is not configured for commercial use with surface supplied air. Always pressurize the Neptune Space RAPTOR gradually by opening the cylinder valve SLOWLY. NEVER lubricate any part of the Neptune Space PREDATOR or cylinder valve with any lubricant. Lubrication must only be performed by an OCEAN REEF trained technician.
  • Page 7 DO NOT leave a cylinder standing unsecured with the Neptune Space PREDATOR attached to the valve. Doing so may cause permanent damage to the Neptune Space and cylinder valve if the cylinder falls over against the first stage. Factory prescribed service for this product must be performed at least once annually by a factory trained OCEAN REEF Service Technician who is employed by an Authorized OCEAN REEF Dealer.
  • Page 8: What's The Correct Size

    The Neptune Space is available in two sizes, Small/Medium and Medium/Large. In order to determine whether a diver should wear a S/M or M/L mask, OCEAN REEF has designed a Mask Measuring Kit. The sizing and measuring system were designed in accordance with the official measuring procedure used in the Los Alamos Scientific Laboratory Charts at the SBCCOM Mask Fit Facility-Aberdeen Proving Ground (Maryland, USA).
  • Page 9: Use Of Conventional Regulator

    Standard connection 200 bar (code 9922) • DIN connection 300 bar (code 9923) • 2 high pressure ports 7/16 -20 UNF • 4 Medium pressure ports 3/8-24 UNF • Flow rate of approx. 4800 l/m at 140 bars NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 10: Air Circulation

    The two equalization silicone caps will move upward and close the nostrils. The silicone caps when correctly positioned should allow breathing through the nose and close the nostrils only when pressing the top part of the mask to equalize. NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 11: Quick Steps

    Don the mask (make sure surface air valve or octopus port is open to allow air in if installed). Completely pull down the central part of the strap and adjust the 6 straps, middle ones NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 12 Breathe normally through your nose or mouth, whichever is most comfortable. To equalize, press the front part of the regulator or the top of the mask(without pushing the purge button). For more information watch the tutorial videos on www.oceanreefgroup.com NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 13: Purging

    When storing the mask, turn the adjustment knob counterclockwise. OCEAN REEF highly recommends that you practice in a pool before using your mask in open water. PURGING The mask can easily be purged in the event that water enters the mask by pressing the exhaust button on the second stage.
  • Page 14: Maintenace And Cleaning/Storage

    -4°F (-20°C) or above +122°F (+50°C). We suggest you use the AC-4 visor protector and the carrying bag included in the package when storing the mask to avoid accidental abrasion (see section 2.4.3). NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 15: Communication

    COMMUNICATION COMMUNICATION APPARATUS The Neptune Space PREDATOR may be used with various communication systems between divers and/or the surface. It is compatible with most underwater communication systems if supplied with the proper adapter and/or DIN connection. Information may be obtained from your OCEAN REEF dealer.
  • Page 16: Troubleshooting

    1st stage intermediate pressure not 140±3 psi / 9.5 9.8 bar. * OCEAN REEF recommends that the regulator be serviced at least once a year, or after 100 dives. This should only be performed by an OCEAN REEF dealer or an authorized OCEAN REEF repair station which uses original spare parts.
  • Page 17 NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 18: Schematic And Parts List (Neptune Space Predator)

    NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 19 O-ring x dive/predive 24 X 2 6963 Hose protector 9311 Dive/predive 6972 O-ring 2025 9673 Nozzle 9672 O-ring 114 9420 Valve body 15532 Demand lever 15448 Wedge 15447 Seat balanced poppet 8866 Balanced poppet 9675 NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 20: Schematic And Parts List (Sl 35Tx)

    SL35TX First stage NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 21 SL35TX First stage NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 22: Warranty

    TheWarranty OCEAN REEF Neptune Space have a limited lifetime warranty to be free of material or manufacturing defects of any component but the regulator ones. Regulator parts are guaranteed to be free of material or manufacturing defects for a period of 24 months from the time the unit is purchased.
  • Page 23 NOTE: NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...
  • Page 24 Fax +1 760 744 9525 E-mail: operator@oceanreefgroup.com d iv ing .o c e a n re e fg ro up .c o m o c e a n re e fg ro up .c o m NEPTUNE SPACE PREDATOR Owner’s Manual rel. 3.4...