1.
COOLING MODE (COOL)
• COOLING MODE (COOL)
• When switched on for the fi rst ti me, the air conditi oner operates in the venti lati on mode.
• Press the MODE butt on to get the functi on selecti on cool.
• The "Cool" LED on the control panel turns on.
• The adjustable temperature range extends from 16 °C to 30 °C.
• In this operati ng mode, the device saves the entered temperature each ti me it is switched off with the ON / OFF
butt on and retains it when it is switched on again.
• The fan speeds as well as the ti mer and SLEEP functi on can also be set in this operati ng mode.
• Set the speed to minimum (low) for quieter operati on.
2.
DEHUMIDIFY MODE (DRY)
• Press the MODE butt on to select the dehumidifi cati on operati ng mode.
• The temperature is controlled by a circuit board and cannot be set.
• In this operati ng mode, the device saves the setti ngs each ti me it is switched off with the ON / OFF butt on and
retains them when it is switched on again.
• The speed of the fan is specifi ed and cannot be set.
NOTE
The air conditi oner does not cool the room when it works in the dehumidify functi on.
If the device is used as a dehumidifi er, the exhaust hose does not have to be connected.
For maximum dehumidifi cati on, leave the exhaust air connecti on on the back free so that the device can discharge
the air directly into the room.
The dehumidifi cati on operati ng mode is recommended in autumn and winter.
When using this functi on in summer, the exhaust air hose should be connected so that the warm air is discharged
outside and not into the room.
The permanent drain should be selected during dehumidifi cati on (see the secti on REMOVING THE CONDENSE
WATER below).
3.
FAN MODE (FAN ONLY)
• Press the MODE butt on to select the venti lati on functi on unti l the corresponding symbol lights up.
• In this operati ng mode, the fan speed can be set.
• However, it is not possible to regulate the temperature.
The device automati cally evaporates the condensed water in cooling mode.
When the air conditi oner is operati ng in cooling mode, the conti nuous drain does not need to be connected; Water can
only accumulate in the device under special climati c conditi ons, when the air humidity is very high. When the internal
tank is full, the air conditi oner emits 8 beeps; the display shows the message H8 and thus the full container. Operati on
of the device is then blocked.
INSTALLING THE CONDENSE DRAIN HOSE
1. Remove the rubber cover on the back (1).
1

MODES OF OPERATION

REMOVE CONDENSATION
2. Mount the clamp (2) on the rear right, near the drain
opening (1), with a screw (3).
1
3
2