novaer K3 3.5 CH00 Instructions Manual

novaer K3 3.5 CH00 Instructions Manual

Mobile air conditioner

Advertisement

Quick Links

DE
EN
MOBILE AIR CONDITIONER
K3 3.5 CH00
INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for novaer K3 3.5 CH00

  • Page 1 MOBILE AIR CONDITIONER K3 3.5 CH00 INSTRUCTIONS...
  • Page 2 If a repair is required, then you can contact your nearest authorized service partner of NOVAER. Repairs should only be executed by qualified professionals for avoiding accidents or damages.
  • Page 3 The appliance shall be stored in a room without any continuously operating ignition sources (for example open flames, an operating gas appliance or an operating electric heater. Do not pierce or burn. Be aware the refrigerants may not contain an odor. The device must be in a room with a floor area of more than 10.3 m .
  • Page 4: Operating And Safety Instructions

    • The unit is equipped with a compressor overload protection system, whereby the compressor only starts once 3 minutes have elapsed from its previous stoppage. • Please wait at least 3 minutes before starting the unit. This helps to prevent the compressor from being damaged.
  • Page 5 • The system socket must always be fitted with an efficient earth connection. • Make sure that the plug is inserted correctly and do not use multiple adapters and ensure the plug is clean. • Never touch the plug with wet hands! •...
  • Page 6: Description Of The Appliance

    with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Page 7 Heating: 7 °C DB / 27 °C DB Dehumidification: 18 °C DB / 35 °C DB Cooling mode room temperature adjustment range: 16 °C DB / 31 °C DB PORTABLE AIR CONDITIONER SETUP The following parts are included in this packaging. Please take them all out of the packaging.
  • Page 8: User Panel

    USER PANEL REMOTE CONTROL Please insert two type AAA batteries into the remote control. 1. SPEED This button regulates the ventilation speed which can only be used in fan, heating and cooling mode. Press this button to adjust to either higher or lower speed. 2.
  • Page 9: On/Off Button

    4. SLEEP While in cooling mode, press the SLEEP key to set the temperature. It increases 1°C after an hour and at most increases 2°C after 2 hours. While in heating mode, press the SLEEP key to set the temperature. It decreases 1°C after an hour and at most decreases 2°C after 2 hours.
  • Page 10 Replace the batteries when depleted. At the end of their working life, batteries must be disposed of separately from unsorted waste. They must be delivered to appropriate separated waste disposal plants or to dealers that provide a similar service. Separate waste disposal of batteries prevents potential negative effects on the environment and human health resulting from inadequate disposal, and also allows the materials from which it is made to be recovered and recycled in order to achieve significant savings in terms of energy and resources.
  • Page 11 • This mobile air conditioner should not be installed in damp rooms / locations. • (1) Turn the housing adapter and the window connector to the ends of the air hose. • (2) Insert the fastening clip of the housing adapter into the openings on the rear of the air conditioning system (see figure below).
  • Page 12: Operating Modes

    kit to the glazier as well. • Insert the Hose Connector (Window End) onto the Hot Air Hose. • Connect the other end of the Hot Air Hose with the appliance Hose Connector (Air Conditioner End) • Avoid curving of the Hot Air Hose. It is recomended to be minimum 40 cm above the ground.
  • Page 13 Room Temperature (Tr) Tr < 23°C 23°C < Tr < 26°C Tr > 26°C Mode Heating Dehumidify Cooling Set Temperature 21°C 23°C 25°C Cooling Mode • Press the “Mode” button till the “Cool” LED icon appears. • Press the “▲”or“ ▼”temperature button to select a desired room temperature between 16°C and 31°C •...
  • Page 14: Troubleshooting

    Fan Mode • Press the “Mode” button till the “Fan” LED icon appears. • Press the “Fan Speed” button to select wind speed. • In this mode the temperature cannot be adjusted. Internal Tank Water Full Alarm Function The inner water tank in the air-conditioner has one water level safety switches, it controls water level.
  • Page 15: Care And Maintenance

    NOT COOL ENOUGH The doors or windows are not closed. Make sure all the windows and doors are closed. There are heat sources inside the room. Remove the heat sources if possible Exhaust air hose is not connected or Connect or clean the exhaust air hose. blocked.
  • Page 16 First clean the surface with soft damp cloth, and then wipe it with a dry cloth. Do not use aggressive detergents, hot water, patrol or any other chemicals, hard brushes for cleaning the surface as this will damage the material of the unit. Neutral detergents or lukewarm water can be used to remove dirt.
  • Page 17 CONTACT If you have questions about the appliance you can always get in touch with NOVAER or the distributor in your country. The contact details of NOVAER can be seen below. For contacting the distributor, you can visit their website for further details.

Table of Contents