8 Configuration instructions on computer

The following figure shows the E220-400T30S configuration host computer display interface, the user can switch to the
command mode through M0M1, and quickly configure and read the parameters on computer.
In the configuration on computer, the module address, frequency channel, network ID, and key are all in decimal mode. The
range of values of each parameter is:
Network address: 0-65535
Frequency channel: 0-83
Network ID: 0-255
Key: 0-65535

9 Hardware design

It is recommended to use a DC stabilized power supply. The power supply ripple factor is as small as possible,
Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co.,Ltd.