Specifications; Troubleshooting - NA-DE 10100 Manual

Switch type motion sensor
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 2
TÜVRheinland
TS EN
60669-2-1
HU-000650
Complies with ROHS Regulation Directive
2002/95/EC
SWITCH TYPE MOTION SENSOR
USAGE AREAS
• At the switch cases
• At the building entrances, stair vestibutes.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.
"OFFERS ENERGY SAVING FEATURE"
GENERAL SECURITY CAUTIONS
• Take off the original package and control if there is any damage of transportation and
general view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist
electricians must install and apply.
CAUTIONS FOR INSTALLATION AND USAGE
• Installing must be carried out professionally in accordance with applicable national wiring
and electrical operating conditions.
• Turn off the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the wall/ceiling.
• Fix the bulbs before operating.
• Use 10A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting
of the time and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the product, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes
such as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-
blank sunshine.
* It can cause the device operate inaccurately if there is tree, brushes etc. in the
coverage area.

SPECIFICATIONS

Operating Voltage
230-240 V~ 50/60 Hz
Detection angle
360° at the Ceiling
180° on the Wall
Mounting Height
2.8 m. at the ceiling
1-2 m. on the wall
Detection Range
9 m. at the ceiling / 8m. on the wall
Time Setting
10 sec. ± 1sec. / 5 min. ± 10 sec.
Lighting Load
Max 1000W Incandescent
Max 400W Fluorescent
Protection Class
IP20
Operating Temperature
-20 °C ~ +40 °C
Power consumption
1.5W
Detection range is determined at the temperature of 20 °C.
SETTING
(e)
(f)
(e) Time Setting
Light ON time can be adjusted continuously from
"10 sec ± 1 sec. / 5 min ± 10 sec." If you turn the knob
clockwise device will operate at minimum time.(10 second)
Control dial set min = Shortest time (10 sec. ± 1 sec.)
Control dial set max = Longest time (5 min. ± 10 sec.)
(f) Daylight Setting
The sensor's response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob clockwise device will operate at dark.
Control dial set
= Daylight operation approx. 2000 lux.
Control dial set
= Night-time operation approx.2 lux.
(d) Switch Setting
Auto = In this mount device will work as a motion sensör.
Off
= Lamb will be always off.
On
= Lamb will be always on.
NOTE : Device will automatically make its own offset by checking environment for
approximately 5 minutes after the first installation. After this period device will operate
normally. If you think the device does not operate normal in first installation, please wait for
5 minutes and start to test again. Be sure that there is no motion by this period.
www.na-de.com.tr • info@na-de.com.tr
‹stanbul Deri Organize Sanayi Bölgesi Tufle Sok. No:8
M1-8 Özel Parsel 34953 Tuzla / ‹STANBUL - TÜRK‹YE
R
10100
10100
CLASS 2
(d)
MOUNTING
(a)
Use this aparate (surface mount aparate) when making
surface mount
Fix the aparate on the wall shown by (a)
Pass the cables through the hole shown by (b)
(b)
(a)
Connect the line cable to the terminal shown by L
Connect the neutral cable to the terminal shown by N
You can also connect the neutral cable of lamb from here
Connect line out cable(for the lamp) to the terminal shown
by LS
L N LS
(f)
(e)
(c)
Fix the product to the surface mount aparate shown by (c)
(d)
when making surface mounting
Fix the product on the wall shown by (c) when making flush
mount
You can select On, Off or Auto mode with the switch shown
by (d)
(c)
DETECTION AREA
Wall
8 m
1-2 m (From base)

TROUBLESHOOTING

MALFUNCTION
CAUSE
• Lamp is off
• Daylight adjustment set to
night-time mode during daytime
operate
• Bulb faulty or there is no
connection
• Power switch off or no electricity
• Fuse faulty
• Switch is at OFF position
• There is no
• Fuse switch off or fuse faulty
electricity on the
device
• Connection faulty.
• Continuously
• Continuously movement in
lamp is on
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.
• Switch is at ON position
• Change perception
• Sudden temperature changes due
area in device
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.
DETECTION AREA
Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature, mounting style and mounting places.
Temperature is very important for operation of motion sensors like all electronic devices.
Using
higher value of loads written on manuals and packages will decrease temperature inside the
device when using Na-De Motion Sensor. As a result detection range will decrease and may
cause defect of electronic components. Environment temperature will also cause decrease
of detection range. Detection range given is determined at 20 °C .If the weather is hot, it will
decrease.
Walking tangential to the sensor
(normal detection range)
The maximum detection range can be realized when walking tangential to the sensor
(Figure 1). When walking directly to the sensor detection range will be low. Because you
will not be able to cut vertical areas. Detection range of 10100 products 9 meters as
diameter 4,5 meters as radius.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will
be met by repair or replacement at our own discretion. The warranty shall not cover damage
to wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice ( date of purchase
and dealer's stamp) to the appropriate Service Center.
Ceiling
4,5 m.
4,5 m.
9 m.
SOLUTION
• Control daylight setting and
re-adjust
• Fit the bulp into the lamp holder,
if it still does not operate, change
the bulb.
• Check the electricity and power
on.
• Change the fuse.
• Select Auto position of switch.
• Check the fuse if necessary use
a new fuse.
• Check the connection cables.
• Check the detection zone.
• Avert it is being detection.
• Change detection zone, change
site of installation.
• Select Auto position of switch.
• Change site of installation or
keep the reasons away.
• Change site of installation.
Figure 1
Walking directly to the sensor
(lover detection range)
KK-10100_150409_EN_00