Download Print this page

Sealey TA201 Instructions page 2

Digital automotive analyser 13 function with ic

Advertisement

3.
SPECIFICATION
DC Voltage (Auto Ranging)
Range
Resolution
400.0mV
0.1mV
4.000V
1mV
40.00V
10mV
400.0V
100mV
1000V
1V
Input Impedance: 10MΩ.
Maximum Input 600Vac rms or 600Vdc.
AC Voltage (Auto Ranging except 400mV)
Range
Resolution
400.0mV
0.1mV
4.000V
1mV
40.00V
10mV
400.0V
100mV
600V
1V
Input Impedance: 10MΩ.
Frequency Range: 50 to 400Hz.
Maximum Input: 600Vac rms or 600Vdc .
Capacitance (Auto Ranging)
Range
Resolution
40.00nF
10pF
400.0nF
0.1nF
4.000uF
1nF
40.00uF
10nF
100.0uF
0.1uF
Input Protection: 250Vac rms or 250Vdc.
Resistance (Auto Ranging)
Range
Resolution
400.0Ω
0.1Ω
4.000kΩ
1Ω
40.00kΩ
10Ω
400.0kΩ
100Ω
4.000MΩ
1kΩ
40.00MΩ
10kΩ
Input Protection: 250Vac rms or 250Vdc.
Diode test
Range
Resolution
0.3mA
1mV
typical
Open Circuit Voltage: 1.5Vdc typical
Overload Protection: 250Vac rms or dc.
Temperature
Range
Resolution
-20°C~+760°C 1°C
-4°F~+1400°F
1°F
Sensor: Type K Thermocouple
RPM (Tacho)
Range
Resolution Accuracy
RPM 4 600~4000RPM
1RPM
600~1200RPM
10RPM
(X 10 RPM)
RPM 2 300~4000RPM
1RPM
/DIS
300~600RPM
10RPM
(x 10 RPM)
Effect Reading: >600RPM
Overload protection 250V ac rms or dc.
Overvoltage Category:
CAT111 600V.
Display:
4000 counts LCD display with function indication.
Polarity:
Automatic, (-) negative polarity indication.
Overrange:
“OL” mark indication.
Low Battery Indication:
The “BAT” is displayed when the battery voltage drops below the operating level.
Measurement Rate:
2 times per second nominal
Auto Power Off:
Meter automatically shuts down after approx 30 minutes of inactivity.
Operating environment:
0°C to 50°C (32° to 122°F) at < 70%relative humidity.
Storage Temperature:
-20° to 60°C (-4°F to 140°F) at <80% relative humidity.
For Inside Use:
Max Working Height:
2000mtr.
Power:
One 9V battery PP9.
Dimensions:
146 (H) x 66.2 (W) x41.5 (D) mm
Approx Weight:
330g
Accuracy is given at 18°C to 28°C (65°F to 83°F) less than 70% relative humidity.
Accuracy
± 0.5% of reading ± 2 digits
±1.5% of reading ± 2 digits
± 1.8% of reading ± 2 digits
Accuracy
± 1.5% of reading ± 30 dig
± 1.0% of reading ± 3 digits
± 1.5% of reading ± 3 digits
± 2.0% of reading ± 2 digits
Accuracy
± 5.0% of reading ± 7 digits
± 3.0% of reading ± 5 digits
± 5.0% of reading ± 5 digits
Accuracy
± 1.2% of reading ± 4 digits
± 1.0% of reading ± 2 digits
± 1.2% of reading ± 2 digits
± 2.0% of reading ± 3 digits
Accuracy
± 10% of reading ±5 digits
Accuracy
± 3.0% of reading ± 3 digits
(Meter only, probe accuracy
not included).
±2% of reading ± 4
digits
Duty Cycle (Auto Ranging)
Range
Resolution
0.1%~99.9%
0.1%
Pulse Width: >100us, <100ms
Frequency Width: 5Hz - 150kHz
Overload Protection: 250Vac rms or dc.
Dwell Angle
Cylinder Range
Resolution
2CYL
0~180.0°
3CYL
0~120.0°
4CYL
0~90.0°
0.1°
5CYL
0~72.0°
6CYL
0~60.0°
8CYL
0~45.0°
10CYL
0~36.0°
Overload Protection: 250Vac rms or dc.
Frequency (Auto Ranging)
Range
Resolution
5Hz
0.001Hz
50Hz
0.01Hz
500Hz
0.1Hz
5kHz
1Hz
50kHz
10Hz
500kHz
100Hz
10MHz
1kHz
Sensitivity: <0.5V rms while <1MHz
Sensitivity: >3V rms while >1MHz
Overload Protection: 250Vac rms or dc.
DC Current (Auto Ranging for uA and mA)
Range
Resolution
400.0uA
0.1uA
4000uA
1uA
40.00mA
10uA
400.0mA
100uA
4A
1mA
10A
10mA
Overload Protection: 0.5A/250V and 20A/250V
Fuse:
Maximum Input:400mAac rms or 400mAdc on uA/mA ranges
20A ac or dc rms on 10A range.
AC Current (Auto Ranging for uA and mA)
Range
Resolution
400.0uA
0.1uA
4000uA
1uA
40.00mA
10uA
400.0mA
100uA
4A
1mA
10A
10mA
Overload Protection: 0.5A/250V and 20A/250V
Fuse:
Frequency Range:50 to 400Hz
Maximum Input: 40mAac or 400mAdc rms on uA/mA ranges,
20Aac rms or dc on 20A range.
Audible Continuity
Audible threshold:
Less than 150Ω
Test Current:
<0.3mA
Overload Protection:
250Vac rms or dc.
Accuracy
± 1.2% of reading ± 2 digits
Accuracy
± 2.0% of reading ± 4 digits
Accuracy
± 1.5% of reading ± 5 digits
± 1.2% of reading ± 3 digits
± 1.5% of reading ± 4 digits
Accuracy
± 1.0% of reading ± 3 digits
± 1.5% of reading ± 3 digits
± 2.5% of reading ± 5 digits
Accuracy
± 1.5% of reading ± 5 digits
± 1.8% of reading ± 5 digits
± 3.0% of reading ± 7 digits
TA201 - 1 - 220404

Advertisement

loading