Troubleshooting - Briggs & Stratton 01813-0 Installation And Owner's Manual

100 amp/200 amp automatic transfer switch
Hide thumbs Also See for 01813-0:
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

Problem
Automatic transfer switch does
not transfer to generator
Automatic transfer switch does
not transfer to utility
Generator is still running after
switch transfers to utility power
Supervised loads (air conditioner,
etc.) are not operating when
utility is present
Briggs & Stratton Power Products Automatic Transfer Switch
Installation and Owner's Manual
Cause
1.
Generator breaker open.
2.
Generator voltage not acceptable.
1.
Service disconnect breaker open.
2.
Utility voltage not acceptable.
Engine cool down period.
NC contacts not operating correctly.
Correction
1.
2.
1.
2.
Engine should stop after 1 minute.
Check NC contact for proper
operation and/or check control wiring
to external load.
9
Reset generator circuit breaker.
Refer to generator manual.
Reset service disconnect breaker.
Wait for utility voltage to return
to normal.