6. Replace screws and thermostat clamp and tighten. Note: The
element retaining screws are tightened only until the return edge
bottoms on the tank flange – do not over tighten.
7. The earthing of the internal storage cylinder relies on a good
electrical contact between the metal surround of the element flange
and the cylinder barrel flange.
An earth continuity test should be performed whenever an element
or element gasket is replaced, adjusted or serviced in any way. This
continuity test is performed between the heaters internal storage
cylinder and the main earth terminal of the water heater with a
resulting reading of not more than 0.5 ohms achieved.
8. Reconnect the element wiring to the thermostat and refit the thermostat cover.
9. Restore cold water supply and fill the storage tank. Release air by gently lifting the
easing lever on the TPR valve until water runs from the drain or opening hot taps.
10. Check for water leaks around the element flange.
11. Conduct an electrical insulation test (refer to "Electrical Insulation Testing" on page
24).
12. Replace access cover securely and restore the power supply to the water heater.
TM074: Stainless Steel Electric Water Heater Service Instructions
REV AB Issued: 07/16
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed "uncontrolled"