Rheem 265 litre Owner's Manual And Installation Instructions

Rheem 265 litre Owner's Manual And Installation Instructions

Gas heavy duty water heater
Hide thumbs Also See for 265 litre:

Advertisement

Owner's Guide
and

Installation Instructions

Gas Heavy Duty
Water Heater
265 litre and 275 litre models
This water heater must be installed and serviced by a qualified person.
Please leave this guide with the householder.

Advertisement

Table of Contents
loading

Summary of Contents for Rheem 265 litre

  • Page 1: Installation Instructions

    Owner’s Guide Installation Instructions Gas Heavy Duty Water Heater 265 litre and 275 litre models This water heater must be installed and serviced by a qualified person. Please leave this guide with the householder.
  • Page 2 PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd. TRADEMARKS ® Registered trademark of Rheem Australia Pty Ltd.
  • Page 3: Table Of Contents

    CONTENTS RESPONSIBLE OFFICER – We recommend you read pages 4 to 16. The other pages are intended for the installer but may be of interest. About Your Water Heater ......................4 Regular Care ..........................8 Water Supplies ........................... 11 Save A Service Call ........................14 Installation ..........................
  • Page 4: About Your Water Heater

    ® The Rheem Heavy Duty Gas water heater model you have chosen is either a 265 litre or 275 litre indoor or outdoor quick recovery water heater. Water is stored in a vitreous enamel lined steel cylinder and heated by a gas burner located under the cylinder.
  • Page 5 Warning: For continued safety of this water heater it must be installed, operated and maintained in accordance with the Owner‟s Guide and Installation Instructions. The Rheem warranty may not cover faults if relief valves or other safety devices are tampered with or if the installation is not in accordance with these instructions.
  • Page 6 ABOUT YOUR WATER HEATER Do not store flammable or combustible materials near the water heater. Flammable liquids (such as petrol), newspapers and similar articles must be kept well away from the water heater and the draught diverter or flue terminal. Gases from some aerosol sprays, stain removers and household chemicals become corrosive when drawn into a flame.
  • Page 7 ABOUT YOUR WATER HEATER HOW DO I KNOW THE WATER HEATER IS INSTALLED CORRECTLY? Installation requirements are shown on pages 24. The water heater must be installed: by a qualified person, and in accordance the installation instructions, and in compliance with Standards AS/NZS 3500.4, AS 5601 or AS/NZS 5601.1, as applicable under local regulations, and all local codes and regulatory authority requirements.
  • Page 8: Regular Care

    Service or their nearest Accredited Service Agent. Note: The annual service and routine replacement of any components, if required, are not included in the Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater.
  • Page 9 Note: The five year service and routine replacement of any components, such as the anode and relief valve(s), are not included in the Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater.
  • Page 10: Regular Care

    If water does not flow freely from the drain line when the lever is lifted, then the water heater must be checked. Phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection. lift until water...
  • Page 11: Water Supplies

    Rheem warranty to apply. ANODE The vitreous enamel lined cylinder of the water heater is only covered by the Rheem warranty when the total dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is used.
  • Page 12 Where the saturation index exceeds +0.40, the water is very scaling. An expansion control valve must be fitted on the cold water line after the non-return valve to protect and for the Rheem warranty to apply to the temperature pressure relief valve and water heater cylinder.
  • Page 13: Water Supplies

    The water heater and its components are not suitable for certain water chemistries. Those chemistries are listed below. If the water heater is connected at any time to a water supply with the following water chemistry, the Rheem warranty will not cover any resultant faults on the components listed below: Water Chemistry Component Total Dissolved Solids (TDS) >...
  • Page 14: Save A Service Call

    The ignition system may have „locked out‟. To reset the water heater, switch the electrical supply off at the isolating switch, wait ten seconds then switch on again. If the water heater fails to light, phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection.
  • Page 15 Code Fault Temperature sensor failure If the fault code is displayed, phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection. BURNER WILL NOT LIGHT Is the fan in the air duct (631 275 model only) operating continuously? Ensure the front cover is securely in position.
  • Page 16 An increase in hot water usage will result in an increase in water heater operation. Has your water heating tariff rate been increased by your gas retailer since your previous account? IF YOU HAVE CHECKED ALL THE FOREGOING AND STILL BELIEVE YOU NEED ASSISTANCE, PHONE RHEEM SERVICE OR THEIR NEAREST ACCREDITED SERVICE AGENT.
  • Page 17: Installation

    INSTALLATION THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the water heater is suitable for the gas type available. (refer to the rating label on the water heater) Note: In Australia, natural gas models can be connected to SNG, however the hourly gas consumption may be reduced (typically by 10%).
  • Page 18 INSTALLATION The water heater must not be installed in an area with a corrosive atmosphere where chemicals are stored or where aerosol propellants are released. Remember the air may be safe to breathe, but when it goes through a flame, chemical changes take place which may attack the water heater. For a single water heater installation, follow the diagrams on pages 24.
  • Page 19 INSTALLATION OUTDOOR INSTALLATION The water heater is to be installed at ground level on a concrete or brick plinth or other fireproof base as approved by the local authority. The water heater must also stand vertically upright with the back of the water heater against or within 25 mm of an external wall or alternatively against a fireproof screen extending at least 500 mm above, below and either side the flue terminal.
  • Page 20 INSTALLATION HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. It is necessary and we recommend that a temperature limiting device be fitted between the water heater and the hot water outlets in any ablution and public areas such as bathrooms, ensuites or public amenities, to reduce the risk of scalding.
  • Page 21 CIRCULATED HOT WATER FLOW AND RETURN SYSTEM If a Rheem water heater is to be installed as part of a circulated hot water flow and return system, a storage water heater able to provide a hot water outlet temperature of at least 60°C must be used. Note: The thermostat must always be set to at least 60°C.
  • Page 22 ANODE The vitreous enamel lined cylinder of the water heater is only covered by the Rheem warranty when the total dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is used.
  • Page 23 INSTALLATION TYPICAL INSTALLATION – OUTDOOR LOCATION 631 275 model shown...
  • Page 24 INSTALLATION TYPICAL INSTALLATION – INDOOR LOCATION 621 275 model shown...
  • Page 25 INSTALLATION DIMENSIONS AND TECHNICAL DATA Model No. 621265 631265 621275 631275 (Indoor) (Outdoor) (Indoor) (Outdoor) Storage capacity (litres) Nominal Dimensions (mm) 1795 1835 1895 1865 1655 1655 1695 1695 36° 36° 36° 36° Weight empty (kg) Hourly Gas Consumption Min. Gas Pressure Test Point Gas Pressure Gas Details (MJ)
  • Page 26: Connections - Plumbing

    CONNECTIONS – PLUMBING All plumbing work must be carried out by a qualified person and in compliance with the Standard AS/NZS 3500.4 and all local codes and regulatory authority requirements. All gas work must be carried out by a qualified person and in compliance with the Standard AS 5601 or AS/NZS 5601.1, as applicable under local regulations, and all local codes and regulatory authority requirements.
  • Page 27 CONNECTIONS – PLUMBING TEMPERATURE PRESSURE RELIEF VALVE The temperature pressure relief valve is shipped in the plastic bag attached to the side of the water heater. The temperature pressure relief valve must be fitted before the water heater is operated. Before fitting the relief valve, make sure the probe has not been bent.
  • Page 28 Warning: Always isolate the water heater before pressure testing the gas supply system. Disconnect the water heater after the isolating cock to prevent the risk of serious damage to the gas control. The Rheem warranty does not cover damage of any nature resulting from failure to observe this precaution. Refer to rating label for gas types and pressures.
  • Page 29: Connections - Electrical

    CONNECTIONS – ELECTRICAL The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. Note: AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in potable water.
  • Page 30 CONNECTIONS – ELECTRICAL THERMOSTAT SETTING The thermostat is adjustable from 60°C to 82°C. For reasons of safety and economy, we advise the thermostat is set at the lowest temperature that will provide sufficient hot water. Discuss the thermostat setting requirements with a responsible officer. Refer to “Temperature Control”...
  • Page 31 1 and 2 directly to the water heater INTERLOCK TERMINAL INTERLOCK TERMINAL 621 SERIES RHEEM RAYPAK B TYPE WIRING DIAGRAM - POWER FLUE CONNECTION multiple water heater installation INTERMITTENT FAN OPERATION-MULTIPLE WATER HEATER Rheem Heavy Duty Gas Water Heaters-621 Series Raypak B Type Water Heaters-B0507 to B4224...
  • Page 32 WIRING DIAGRAM - 24 HR FAN OPERATION POWER FLUE CONNECTION MULTIPLE and SINGLE RHEEM 621 SERIES & RAYPAK TYPE A SERIES (197- 427) 1. Power source for the water heater, fan and control circuit must be from the same circuit.
  • Page 33: Multiple Installations

    MULTIPLE INSTALLATIONS A multiple installation of Rheem water heaters on a single manifold or multiple manifolds is possible, using ® the Rheem Equa-Flow manifold system, where large volumes of hot water are required. The Equa-Flow principle will function with water heaters in line, around a corner or in rows back to back...
  • Page 34 MULTIPLE INSTALLATIONS In Line Manifold Single Bank of Water Heaters Multiple Banks of Water Heaters Angle Manifold Back to Back Manifold TPR Valve Drain Line Common Discharge Point...
  • Page 35 MULTIPLE INSTALLATIONS TYPICAL INSTALLATION – RHEEM HEAVY DUTY GAS WATER HEATERS LEGEND RHEEM COMMERCIAL WATER HEATERS TYPICAL INSTALLATION INSTALLATION DIMENSIONS – RHEEM HEAVY DUTY GAS WATER HEATERS In Line Manifold Angle Manifold Back to Back Manifold Installation Layout Minimum Dimensions...
  • Page 36 MULTIPLE INSTALLATIONS MANIFOLD ARRANGEMENT Hot Manifold Assembly Cold Manifold Assembly...
  • Page 37: Commissioning

    COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. Open all of the hot water tap(s) in the building (don‟t forget the showers) and supply cock(s) and valve(s) in the system.
  • Page 38: Lighting The Water Heater

    If the water heater fails to light, phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection. (Qualified person only: refer to “Diagnostic Features of Hot Surface Ignition Control”...
  • Page 39 40). Check the test point pressure and compare with the rating label. Adjust if necessary. If unable to get the water heater working properly, contact Rheem Service or their nearest Accredited Service Agent to arrange for an inspection. When satisfied everything is working properly instruct the user in the correct method of operation.
  • Page 40: Draining The Water Heater

    LIGHTING THE WATER HEATER BURNER PRESSURE ADJUSTMENT Switch off the electrical supply at the isolating switch. Attach a manometer to the test spigot at side of gas control. Switch on the electrical supply at the isolating switch. Check the gas pressure (refer to data plate). If necessary adjust the regulator under the cap on top of the gas control.
  • Page 41: Temperature Control

    TEMPERATURE CONTROL HOTTER WATER INCREASES THE RISK OF SCALD INJURY. This water heater can deliver water at temperatures which can cause scalding. It is necessary and we recommend that a temperature limiting device be fitted between the water heater and the hot water outlets in any ablution and public areas such as bathrooms, ensuites or public amenities, to reduce the risk of scalding.
  • Page 42 TEMPERATURE CONTROL THERMOSTAT ADJUSTMENT The water heater is supplied with the thermostat preset at 70°C. It will be necessary to adjust the thermostat temperature setting if another temperature is required. When adjusting the thermostat temperature it is necessary to alter the thermostat offset. The table outlines the thermostat temperature and the corresponding offset.
  • Page 43 2.1 The decision of whether to repair or replace a faulty component is at Rheem’s sole discretion. 2.2 If you require a call out and we find that the fault is not covered by the Rheem warranty, you are responsible for our standard call out charge.
  • Page 44: Warranty

    3. WHAT IS COVERED BY THE RHEEM WARRANTY FOR THE WATER HEATERS DETAILED IN THIS DOCUMENT 3.1 Rheem will repair or replace a faulty component of your water heater if it fails to operate in accordance with its specifications as...

This manual is also suitable for:

275 litre275265

Table of Contents