Digikeijs DR4088CS Manual
Hide thumbs Also See for DR4088CS:

Advertisement

DR4088 CS / GND / OPTO
DR4088CS
DR4088GND
HANDLEIDING / MANUAL
BEDIENUNGSANLEITUNG / MANUEL
V1.0 17 Oktober 2011
© Copyright 2005 – 2015 Digikeijs, the Netherlands.
All rights reserved. No information, images or any
part of this document may be copied without the
prior written permission of digikeijs.
www.digikeijs.com
P 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DR4088CS and is the answer not in the manual?

Questions and answers

Summary of Contents for Digikeijs DR4088CS

  • Page 1 HANDLEIDING / MANUAL BEDIENUNGSANLEITUNG / MANUEL V1.0 17 Oktober 2011 © Copyright 2005 – 2015 Digikeijs, the Netherlands. All rights reserved. No information, images or any part of this document may be copied without the prior written permission of digikeijs.
  • Page 2: Garantie

    Veuillez lire ce manuel attentivement. Les dommages causés par le non suivi des instructions du manuel ne seront pas couverts par la garantie. En outre, nous ne sommes pas responsable d’autres dommages résultant du non suivi des instructions de ce manuel. www.digikeijs.com...
  • Page 3: Beschrijving Van Het Product

    Aantal Geschikt Stroomver- Minimale Maximale Piek Ingangen voor bruik belasting belasting belasting DR4088CS 2 x 8 2 Rail 12mA 2 Ampère 5 Ampère continue DR4088 GND / OPTO 1x 16 3 Rail 12mA General A constant flow of track occupation information is essential for monitoring a model railway with a PC or route control system (Marklin Memory, IB switch).
  • Page 4: Technische Details

    Technische Details Anzahl der Passend Strombedarf Minimal Maximal Spitzenbelas- Eingänge für belastung belastung tung DR4088CS 2 x 8 2 Rail 12mA 2 Ampère 5 Ampère continue DR4088 GND / OPTO 1x 16 3 Rail 12mA Général Pour surveiller un chemin de fer miniature avec un PC ou un système de contrôle de la route (Marklin Memory, interrupteur IB), il faut un flux d’informations constant.
  • Page 5 DR60886 und STP Kabeln DR60886 en STP kabels. Exemple de connexion avec adaptateur de prise Connection example with plug adapter DR60886 et câbles STP DR60886 and STP cables DR60886 INPUT INPUT INPUT 1 - 16 17 - 32 33-49 www.digikeijs.com...
  • Page 6 DR4088 CS / GND / OPTO 3-RAIL VOORBEELDEN (C en K rails) 3-SCHIENEN BEISPIELE (C und K Schienen) 3-RAIL EXAMPLES (C and K rails) EXEMPLES 3-RAILS (rails C et K) www.digikeijs.com...
  • Page 7 DR4088 CS / GND / OPTO 2-RAIL VOORBEELD 2-SCHEINEN BEISPIEL 2-RAIL EXAMPLE EXEMPLE 2-RAILS Getrennter Stromkreis Gescheiden stroomkring Circuit séparé Separate circuit BOOSTER www.digikeijs.com...
  • Page 8 Also available aussi disponible Type / Typ Lengte / length Länge / longueur DR60887 25 CM DR60880 50 CM DR60881 DR60882 DR60883 DR60884 DR60885 DR60886 S88 Verloopstekker DR60886 S88 Stecker-Adapter DR60886 S88 plug adapter DR60886 S88 adaptateur WWW.DIGIKEIJS.COM www.digikeijs.com...