Walter AXIO Mounting Instructions

Automatic slatted pool covers

Advertisement

Quick Links

AXIO
Safety cover compliant with French NFP 90-308 norm to be installed and used according this mounting user manual
Mounting instructions
Please read the Operation Manual completely and retain for future reference
AUTOMATIC
SLATTED
COVERS MANUFACTURER
POOL
Compliant with French NFP 90-308 standard

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AXIO and is the answer not in the manual?

Questions and answers

Summary of Contents for Walter AXIO

  • Page 1 POOL COVERS MANUFACTURER Compliant with French NFP 90-308 standard AXIO Safety cover compliant with French NFP 90-308 norm to be installed and used according this mounting user manual Mounting instructions Please read the Operation Manual completely and retain for future reference...
  • Page 2: Specifications

    Upon receipt of the slatted automatic cover: WALTER Piscine can not be held responsible for losses or damages caused during the transport. It is clearly stated that the goods travel at recipient's risk. In case of missing or defective parts, it is essential to: - Record any reservations on the delivery note.
  • Page 3 A - Anodised aluminium axle + motor B - Shaft + rinas. oooosite to the motor C - Electrical box D - Quick fastening system (qty depending on the width of the pool) E - Axle support flange, beam support and alignment wedge F - Rolling straps tobe fixed on the axle (qty depending of the width of the pool) G - 50 cm slat strips (6 slats/strip) (qty depending of the length of the pool) H - .
  • Page 4 Submerged system AXIO...
  • Page 5 SHAFT WITH MASONRY SEPARATION WALL...
  • Page 6 Wall fastening...
  • Page 7 Angle mounting...
  • Page 8 PIT WITH PREFABRICATED SEPARATION WALL IN PVC...
  • Page 9 Wall fastening...
  • Page 10 Angle mounting...
  • Page 11 SETTING UP OF THE AXIS...
  • Page 12 INSTALLATION OF THE BEAM AND GRATINGS...
  • Page 13 Beam is-cover connecting strap Supply REP. Description Quantity WALTER Submerged electric motor Anodised aluminium axle diameter 167 mm Stainless steel screws Tb Z - M5.5x32 Aliqnment wedqe Stainless steel screw TF HC - M6 x 30 Knack-in dowel Technyl !lange...
  • Page 14 INSTALLATION OF THE SLATS...
  • Page 15: Cover Assembly

    Cover assembly ASSEMBLAGE DE LA COUVERTURE Cover assembly must be done when the pool is filled with water > Make up and down movements until the slats are locked together > You have to spread the lateral play on the pool cover >...
  • Page 16 ANTI-LIFTING DEVICE - POSITIONING OF THE ANTI-LIFTING LOOPS...
  • Page 17: Electrical Connection

    ELECTRICAL CONNECTION...
  • Page 18 CONTROL UNIT WITH PLC For SIREM motorisations for automatic underwater swimming pool coverings.
  • Page 19: Card Details

    CARD DETAILS Power transformer Motor direction 200 VA rotation controls Auto/Manual button Fuse ATO 15A Automaton Varistor Power supply terminal block • Motor power cable terminal block Terminal block details Electrolyser terminal block, control, rev counter sensor BOX DIMENSIONS +-------- :::...
  • Page 20 NT-5053-1-01-FR INSTRUCTIONS FOR USE 1st Step Home screen when first switched on . SIREM -.-' 2 . iJ It is possible to test the wiring of the control box by pressing the key HPPU'::let' ::. u r H either on opening or closing . For safety reasons, the motor cannot be operated until the installer has pressed the A key .
  • Page 21 NT-5053-1-01-FR INSTRUCTIONS FOR USE �' 0[U3. [1 1 3 R 04'3:35 1 1F1f-U1F1 R;p,:i�. - erm�e M B=Pos . . 1 e rt. e M i:11J 1 Memorise the open position by pressing B Confirmation of memorisation: An M appears next to "open pos". 5th Step 04985 000.00R...
  • Page 22: Error Messages

    NT-5053-1-01-FR INSTRUCTIONS FOR USE ERROR MESSAGES ERROR MESSAGES The signal from the rev counter sensor does not change its status. 04985 UUU,UUH 11(1000+..r. m in Rrr�t_. Erreur ,:..3p+_.eur The system locks up. Only a new initialization can restart the system. Check the sensor connection Cycle Error The motor is powered continuously for 5 minutes.
  • Page 23: Important Advices

    - Fastening system are fitted with stainless hex head cap screws, as well as sealing gaskets in order to lock the straps, please click both parts together. Walter remains at user's disposal for any further advice or information. Cover installation...
  • Page 24: Maintenance Tips

    Maintenance tips The pool user is responsible for keeping his cover in good conditions. He must clean his cover twice a year with a high pressure water cleaner and use a food descaling product and no solvent or abrasive product. In order to keep a right water balance, without risks for the cover, following regulations are recommended : PH betwen 7.2 and 7.6 Chlor between 0.7 and 1.5...
  • Page 25 Warranty The warranty is granted when normal installation, use and wintering are in line with our conditions. WALTER Pscine warrants all defective parts replacement during the warranty period as of the service enter date. Automatic cover installation and repair must be performed by a qualified technician.
  • Page 26: Safety Tips

    Safety tips Even if your pool is secure, please be aware that : a responsible adult must always be present when the pool is open > There is no substitute for individual responsability. Constant adult supervision constitutes the best protection for young children. >...
  • Page 27 A pool might represent a serious danger for your children. Drowning happens in a few minutes. Please maintain constant vigilance and an active monitoring when children are nearby the pool, even if they can swim. An adult must always be present when the pool is open...

Table of Contents