DANGER! DO NOT direct the output jet of air towards people or animals.
s
DO NOT
s
DO NOT
p WARNING! The air tank is a pressure vessel and the following safety measures apply:
DO NOT tamper with the safety valve and DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank.
DO NOT subject the tank to impact, vibration or to heat and DO NOT allow contact with abrasives or corrosives.
DO drain condensation from tank daily and inspect inside walls for corrosion every three months and have a detailed tank inspection
carried out annually.
The tank shell must not fall below the certified thickness at any point.
WARNING! If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.
p
p
2.
INTRODUCTION & SPECIFICATIONS
2.1.
Specification
3.
PREPARATION
p WARNING! The compressor is shipped without oil in the pump. Do not start the compressor until it has been filled with oil (see below).
4.
OPERATION
WARNING! Ensure that you have read, understood and apply Section 1 safety instructions.
p
p
4.1.
IMPORTANT. The use of extension leads to connect this compressor to the mains is not recommended as the resulting
voltage drop reduces motor, and therefore pump, performance.
4.2.
Take care when selecting tools for use with the compressor. Air tool manufacturers normally express the volume of air
required to operate a tool in cubic feet per minute (cfm). This refers to free air delivered by the compressor (air out) which
varies according to the pressure setting. Do not confuse this with the compressor displacement which is the air taken in by
the compressor (air in). Air out is always less than air in - due to losses within the compressor .
fig. A
fig. 2