Lütze DIOLINE20 Operation Instructions Manual

Lütze DIOLINE20 Operation Instructions Manual

Digital i/o modules
Hide thumbs Also See for DIOLINE20:
Table of Contents

Advertisement

Quick Links

Operation Instructions
DIOLINE20
Digital I/O Modules
Version 4.50

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIOLINE20 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lütze DIOLINE20

  • Page 1 Operation Instructions DIOLINE20 Digital I/O Modules Version 4.50...
  • Page 2 Lütze Transportation GmbH Bruckwiesenstraße 17-19 D-71384 Weinstadt Tel.: +49 (0) 7151 6053-545 Fax: +49 (0) 7151 6053-6454 Sales.Transportation@luetze.de www.luetze-transportation.de...
  • Page 3: Table Of Contents

    ▪ Digital I/O Modules Content Content Introduction....................... 1 General Information..................2 Symbol Description........................2 Copyright ............................. 2 Disclaim of Liability ........................2 Related Documents ........................3 Safety ......................... 4 Content of the Manual ......................... 4 Intended Use ..........................4 Recepients........................... 4 Operating Employees ........................
  • Page 4 ▪ Digital I/O Modules Content 11.2.3Technical Data........................... 39 11.2.4Connecting the Digital Outputs ....................41 11.2.5Operation ........................... 43 11.3 4x2 Digital Outputs DC 24 V with Diagnosis 4x2 Digital Outputs DC 24 V with Diagnosis – redundancy capable ......... 45 11.3.1Product Assembly........................45 11.3.2LED Display ..........................
  • Page 5: Introduction

    ▪ Digital I/O Modules Introduction Introduction This manual is part of the Digital I/O Modules. It contains important information about the handling and safety. To avoid hazardous situations read the manual before installing the product and using it. Store the manual at a handy place. If selling, renting or in case of a divestiture pass the manual to the authorize person.
  • Page 6: General Information

    ▪ Digital I/O Modules General Information General Information Symbol Description The manual contains several safety messages. Each safety message contains a defined signal word and a color. The color and the word are referring to an alert level. There are 4 levels. The safety messages point out hazardous situations and give information to avoid those.
  • Page 7: Related Documents

    ▪ Digital I/O Modules General Information Related Documents The digital I/O modules are always operated with different PLCs and buscoupler. Read the manual of the PLC or buscoupler before using the I/O modules.
  • Page 8: Safety

    Intended Use The DIOLINE20 I/O modules are designed for the exclusive use in railway vehicles, as: ▪ In- and output for signals which are controlled by a busnode or a PLC Use the I/O modules only for the listed cases and only with external devices recommended and allowed by Lütze Transportation GmbH.
  • Page 9: Protective Clothing And Equipment

    ▪ Digital I/O Modules Safety ▪ The operator is responsible to train the employees and to inform himself about the industrial safety regulation. ▪ The operator is responsible that safety, environment protection regulations and rules for accident prevention are observed. ▪...
  • Page 10: Product Overview

    ▪ Digital I/O Modules Product Overview Product Overview Product Description The DIOLINE20 I/O Modules are connected to a buscoupler or PLC via the L-Bus (Lütze Bus). The I/O Modules are available as: Type 8 digital Inputs 8 digital Outputs 16 digital Inputs...
  • Page 11: System Overview

    Digital I/O Modules Product Overview System Overview The I/O modules can be integrated in the product line of the DIOLINE20 automating system as follows. The DIOLINE product line contains modular components. A unit consists of a controller with an integrated CPU and an extension module. It is possible to connect max.
  • Page 12: Field Of Application

    ▪ Digital I/O Modules Product Overview Field of Application The DIOLINE20 I/O Modules can be connected to buscoupler or PLCs.
  • Page 13: Transport And Storing

    ▪ Digital I/O Modules Transport and Storing Transport and Storing Protect the product against humidity. Store the product in a dry room between -40 and 85°C. Make sure that the I/O modules are safely packaged for transporting, to absorbe possible crushes. Dust can destroy electronic components.
  • Page 14: Scope Of Delivery

    ▪ Digital I/O Modules Scope of Delivery Scope of Delivery ▪ DIOLINE20 I/O Module ▪ Plug-in Connector ▪ Instruction Leaflet...
  • Page 15: General Technical Data

    ▪ Digital I/O Modules General Technical Data General Technical Data Mechanics Dimensions (WxHxD) 57.0x141.5x48.0 mm Housing aluminum Mounting top hat rail Electronic Module Supply Voltage Supply DC 16.8-30 V Ripple max. 10 % Enviromental Condition Operating Temperature -40°C to +70°C (+85°C for 10 min) according to EN 50155 class TX Storage Temperature range min./ -40°C bis +85°C...
  • Page 16 ▪ Digital I/O Modules General Technical Data Standards EN 50155 Electronic equipment on railway vehicles EN 50121 Electromagnetic compability EN 50124 Insulation coordination EN 61373 Vibration and shocks For detailled standard information, please see the technical data sheet.
  • Page 17: Mounting

    ▪ Digital I/O Modules Mounting Mounting Risk of injury by electric current. People can be injured by electric current and the product can be damaged. Deenergize the system before mounting. Mount the product with a distance of 5 mm minimum to other products, to provide good air conditions.
  • Page 18: Initial Operation - Hardware

    ▪ Digital I/O Modules Initial Operation – Hardware Initial Operation – Hardware The initial operation has to be done by electricians. To connect the modules correctly read the chapter of the required module. In the chapters you will also find information about the pin assignments. Power Supply The built in microcontroller of the digital I/O module is feeded by the L-Bus interface.
  • Page 19: L-Bus - Interface

    Initial Operation – Hardware L-Bus – Interface The L-Bus interface is for coupling the local DIOLINE20 I/O modules. The L-Bus, (Lütze-Bus) is a special fieldbus invented by company Lütze. Switch off the power when connecting or disconnecting the I/O modules.
  • Page 20 ▪ Digital I/O Modules Initial Operation – Hardware 2. Connect the DIOLINE 20 I/O modules via the L-Bus Interface. Fig. 2: L-Bus Master 3. Switch on the power. Fig. 3: MVB Buscoupler with I/O Modules 4. The „LB“ LED is green. The devices are ready for operation.
  • Page 21: Digital Inputs

    Digital Inputs 10.1 Characteristics ▪ Low-Pass Filter Disables errors which are smaller than the typical cycletime. ▪ Insulation Channel Enables potential separation between the inputs and the system bus. And also between the inputs of the different groups. ▪ Antiparallel Diode Avoids the damage of entry levels at the confusing of poles of the input and the ground.
  • Page 22: 2X8 Digital Inputs Dc 24, 72, 110 V

    ▪ Digital I/O Modules Digital Inputs 10.2 2x8 Digital Inputs DC 24, 72, 110 V 10.2.1 Product Assembly L-Bus Interface – incoming LED Diagnosis Display – L-Bus L-Bus Interface – outgoing Connector Digital Inputs Connector Digital Inputs Neutral Conductor – Mounting Tab LED Diagnosis Display –...
  • Page 23: 2Led Display

    ▪ Digital I/O Modules Digital Inputs 10.2.2 LED Display 10.2.2.1 LEDs – L-Bus Color Status green active Error 10.2.2.2 LEDs – Input Signals Color Status 1-16 yellow Sensor active...
  • Page 24: 3Technical Data

    ▪ Digital I/O Modules Digital Inputs 10.2.3 Technical Data Inputs 24 V Module Number Data Width in the Process Image 2 Byte Inputs Current Consumption at DC 24 V nom. 10 mA Potential Insulation Insulation Voltage ▪ AC 1.5 kV inputs and electronic ▪...
  • Page 25 ▪ Digital I/O Modules Digital Inputs Inputs 72 V Module Number Data Width in the Process Image 2 Byte Inputs Current Consumption at DC 24 V nom. 10 mA Potential Insulation Insulation Voltage ▪ AC 1.5 kV inputs and electronic ▪...
  • Page 26 ▪ Digital I/O Modules Digital Inputs Inputs 110 V Module Number Data Width in the Process Image 2 Byte Inputs Potential Insulation Voltage Insulation ▪ AC 1.5 kV inputs and electronic ▪ AC 1.5 kV input potential against each other Input Voltage “0“...
  • Page 27: 4Connecting The Digital Inputs

    ▪ Digital I/O Modules Digital Inputs 10.2.4 Connecting the Digital Inputs Connect the digital inputs via the cage clamps X1 and X2. Follow these steps: 1. Switch off the power. 2. Connect the inputs regarding the pin assignment and the signals. Digitale Inputs 24, 72 and 110 V (2 Potentials) Cage Clamp X1...
  • Page 28 ▪ Digital I/O Modules Digital Inputs Cage Clamp X2 Signal Description 0 V - Potential A DI 5 Input 5 DI 6 Input 6 DI 7 Input 7 DI 8 Input 8 (1st Byte MSB) DI13 Input 13 DI14 Input 14 DI15 Input 15 DI16...
  • Page 29: 5Operation

    ▪ Digital I/O Modules Digital Inputs 10.2.5 Operation 10.2.5.1 Block Diagram 2x8 Digital Inputs 24 V...
  • Page 30 ▪ Digital I/O Modules Digital Inputs 10.2.5.2 Block Diagram 2x8 Digital Inputs 72 V...
  • Page 31 ▪ Digital I/O Modules Digital Inputs 10.2.5.3 Block Diagram 2x8 Digital Inputs 110 V...
  • Page 32: 4X4 Digital Inputs Dc 24 And 72 V

    ▪ Digital I/O Modules Digital Inputs 10.3 4x4 Digital Inputs DC 24 and 72 V 10.3.1 Product Assembly L-Bus Interface – outgoing LED Diagnosis Display – L-Bus L-Bus Interface – incoming Connector Digital Inputs Connector Digital Inputs Neutral Conductor – Mounting Tab LED Diagnosis Display –...
  • Page 33: 2Led Display

    ▪ Digital I/O Modules Digital Inputs 10.3.2 LED Display 10.3.2.1 LEDs – L-Bus Color Status green active Error 10.3.2.2 LEDs – Input Signals Color Status 1-16 yellow Sensor active...
  • Page 34: 3Technical Data

    ▪ Digital I/O Modules Digital Inputs 10.3.3 Technical Data Inputs 24 V Module Number Data Width in the Process Image 2 Byte Inputs Current Consumption at 24 V DC nom. 10 mA Potential Insulation Insulation Voltage ▪ AC 1.5 kV inputs and electronic ▪...
  • Page 35 ▪ Digital I/O Modules Digital Inputs Input 72 V Module Number Data Width in the Process Image 2 Byte Inputs Current Consumption at 24 V DC nom. 10 mA Potential Insulation Voltage Insulation ▪ AC 1.5 kV inputs and electronic ▪...
  • Page 36: 4Connecting The Digital Inputs

    ▪ Digital I/O Modules Digital Inputs 10.3.4 Connecting the Digital Inputs Connect the digital inputs via the cage clamps X1 and X2. Proceed as follows: 1. Switch off the power. 2. Connect the inputs regarding the pin assignment and the signals. Digital Inputs 24 and 72 V (4 Potentials) Cage Clamp X1...
  • Page 37 ▪ Digital I/O Modules Digital Inputs Cage Clamp X2 Signal Description 0 V - Potential A DI 5 Input 5 DI 6 Input 6 DI 7 Input 7 DI 8 Input 8 (1st Byte MSB) DI13 Input 13 DI14 Input 14 DI15 Input 15 DI16...
  • Page 38: 5Operation

    ▪ Digital I/O Modules Digital Inputs 10.3.5 Operation 10.3.5.1 BLock Diagram 4x4 Digital Inputs 24 V...
  • Page 39 ▪ Digital I/O Modules Digital Inputs 10.3.5.2 Block Diagram 4x4 Digital Inputs 72 V...
  • Page 40: Digital Outputs

    Digital Outputs 11.1 Characteristics ▪ Low-Pass Filter Disables errors which are smaller than the typical cycletime. ▪ Insulation Channel Enables potential separation between the inputs and the system bus. And also between the inputs of the different groups. ▪ Suppressor Diode Surge protection ▪...
  • Page 41: 2X8 Digital Outputs 24 V Dc 2X8 Digital Outputs 24 V Dc - Redundancy Capable

    ▪ Digital I/O Modules Digital Outputs 11.2 2x8 Digital Outputs 24 V DC 2x8 Digital Outputs 24 V DC – redundancy capable 11.2.1 Product Assembly L-Bus Interface – incoming LED Diagnosis Display – L-Bus L-Bus Interface – outgoing LED Diagnosis Display – Digital Inputs Connector Digital Outputs Connector Digital Outputs Neutral Conductor –...
  • Page 42: 2Led Display

    ▪ Digital I/O Modules Digital Outputs 11.2.2 LED Display 11.2.2.1 LEDs – L-Bus Color Status green active Error 11.2.2.2 LEDs – Output Signals Color Status 1-16 yellow Sensor active green Supply OK Overload green Supply OK Overload...
  • Page 43: 3Technical Data

    ▪ Digital I/O Modules Digital Outputs 11.2.3 Technical Data Outputs for 24 V Moduls Number Data Width in the Process Image 2 Byte Inputs Current Consumption at DC 24 V nom. 10 mA Potential Insulation Voltage Insulation ▪ AC 1.5 kV inputs and electronic ▪...
  • Page 44 ▪ Digital I/O Modules Digital Outputs Outputs 24 V Module redundancy capable Number 16 thereof 8 capable of redundancy Data width in the process image 2 Byte Outputs Current Consumption at DC 24 V nom. 10 mA Potential Insulation Insulation Voltage ▪...
  • Page 45: 4Connecting The Digital Outputs

    ▪ Digital I/O Modules Digital Outputs 11.2.4 Connecting the Digital Outputs Connect the digital outputs via the cage clamps X1 and X2. Follow these steps: 1. Switch off the power. 2. Connect the outputs regarding the pin assignment and the signals. Digital Outputs 24 V (redundant compatible) Cage Clamp X1...
  • Page 46 ▪ Digital I/O Modules Digital Outputs Cage Clamp X2 Signal Description 0 V - Potential A DO 5 Output 5 DO 6 Output 6 DO 7 Output 7 DO 8 Output 8 (1st Byte MSB) DO 13 Output 13 DO 14 Output 14 DO 15 Output 15...
  • Page 47: 5Operation

    ▪ Digital I/O Modules Digital Outputs 11.2.5 Operation 11.2.5.1 Block Diagram 2x8 Digital Outputs 24 V...
  • Page 48 ▪ Digital I/O Modules Digital Outputs 11.2.5.2 Block Diagram 2x8 Digital Outputs 24 V redundancy capable...
  • Page 49: 4X2 Digital Outputs Dc 24 V With Diagnosis 4X2 Digital Outputs Dc 24 V With Diagnosis - Redundancy Capable

    ▪ Digital I/O Modules Digital Outputs 11.3 4x2 Digital Outputs DC 24 V with Diagnosis 4x2 Digital Outputs DC 24 V with Diagnosis – redundancy capable 11.3.1 Product Assembly L-Bus Interface – incoming LED Diagnosis Display – L-Bus L-Bus Interface – outgoing LED Diagnosis Display –...
  • Page 50: 2Led Display

    ▪ Digital I/O Modules Digital Outputs 11.3.2 LED Display 11.3.2.1 LEDs – L-Bus Color Status green active Error 11.3.2.2 LEDs – Input Signals Color Status yellow Actor active green Supply OK Overload green Supply OK Overload green Supply OK Overload green Supply OK Overload...
  • Page 51: 3Technical Data

    ▪ Digital I/O Modules Digital Outputs 11.3.3 Technical Data Outputs 24 V Module Number Data width in the process image 1 Byte Output 2 Byte Input Byte 1 = Read-back outputs Byte 2 = Status of the output driver Current Consumption DC 24 V nom.
  • Page 52 ▪ Digital I/O Modules Digital Outputs Outputs 24 V Module redundancy capable Number 8 redundancy capable Data width in the process image 1 Byte Outputs Current Consumption at DC 24 V nom. 10 mA Potential Insulation Voltage Insulation ▪ AC 1.5 kV outputs and electronic ▪...
  • Page 53: 4Connecting Digital Outputs

    ▪ Digital I/O Modules Digital Outputs 11.3.4 Connecting Digital Outputs Connect the digital outputs via the cage clamps X1 and X2. Proceed as follows: 1. Switch off the power. 2. Connect the outputs regarding the pin assignment and the signals. Digital Outputs 24 V (capable of redundancy) –...
  • Page 54 ▪ Digital I/O Modules Digital Outputs Cage Clamp X2 Signal Description 0 V - Potential A DO 2 Output 2 Not connected 0 V - Potential B DO 4 Output 4 DO 6 Output 6 0 V - Potential C Not connected DO 8 Output 8...
  • Page 55: 5Diagnosis

    ▪ Digital I/O Modules Digital Outputs 11.3.5 Diagnosis The error status of the output driver is entered in the status byte. For every output one byte is entered. The module status flags stays “0“. There is no Hardware error if the output is 0. If the output is “1“ there is an overload on the output channel.
  • Page 56: 6Operation

    ▪ Digital I/O Modules Digital Outputs 11.3.6 Operation 11.3.6.1 Block Diagram 4x2 Digital Outputs 24 V...
  • Page 57 ▪ Digital I/O Modules Digital Outputs 11.3.6.2 Block Diagram 4x2 Digitale Outputs 24 V – redundancy capable...
  • Page 58: Digital Outputs Dc 110

    ▪ Digital I/O Modules Digital Outputs 11.4 6 Digital Outputs DC 110 V 6 Digital Outputs DC 110 V – redundancy capable 11.4.1 Product Assembly L-Bus Interface – incoming LED Diagnosis Display – L-Bus L-Bus Interface – outgoing LED Diagnosis Display – Digital Outputs Connector Digital Outputs Connector Digital Outputs Neutral Conductor –...
  • Page 59: Led Display

    ▪ Digital I/O Modules Digital Outputs 11.5 LED Display 11.5.1 LEDs – L-Bus Color Status green active Error 11.5.2 LEDs – Output Signals Color Status yellow Output active...
  • Page 60: 3Technical Data

    ▪ Digital I/O Modules Digital Outputs 11.5.3 Technical Data Output 110 V Module Number Data Width in the Process Image 1 Byte Outputs 2 Byte Inputs Byte 1 = Read-back outputs Byte 2 = Status of the output driver Current Consumption at DC 24 V nom.
  • Page 61 ▪ Digital I/O Modules Digital Outputs Output 110 V Module redundancy capable Number 6 redundancy capable Data Width in the Process Image 1 Byte Outputs 2 Byte Inputs Byte 1 = Read-back outputs Byte 2 = Status of the output driver Current Consumption at DC 24 V nom.
  • Page 62: 4Connecting The Digital Outputs

    ▪ Digital I/O Modules Digital Outputs 11.5.4 Connecting the Digital Outputs Connect the digital Outputs in 3 groups via the two cage clamps X1 and X2. Follow these steps: 1. Switch off the power. 2. Connect the outputs regarding the pin assignment and the signals.
  • Page 63: 5Diagnosis

    ▪ Digital I/O Modules Digital Outputs 11.5.5 Diagnosis The error status of the output driver is entered in the status byte. For every output one byte is entered. The module status flags stays “0“. There is no Hardware error if the output is 0. If the output is “1“ there is an overload on the output channel.
  • Page 64: 6Operation

    ▪ Digital I/O Modules Digital Outputs 11.5.6 Operation 11.5.6.1 Block Diagram 6 Digital Outputs 110 V...
  • Page 65 ▪ Digital I/O Modules Digital Outputs 11.5.6.2 Block Diagram 6 Digital Outputs 110 V – redundancy capable...
  • Page 66: Digital Combination

    Digital Combination 12.1 Characteristics ▪ Module with In- and Outputs Same characteristics as the corresponding in- and output modules ▪ The four inputs and outputs inside a group have the same potential.
  • Page 67: 2X4/2X4 Digital Combi Module Dc 24 V

    ▪ Digital I/O Modules Digital Combination 12.2 2x4/2x4 Digital Combi Module DC 24 V 12.2.1 Product Assembly L-Bus Interface – incoming LED-Diagnosis Display – L-Bus L-Bus Interface – outgoing Connector Digital Inputs Connector Digital Inputs Neutral Conductor – Mounting Tab LED-Diagnosis Display –...
  • Page 68: 2Led Display

    ▪ Digital I/O Modules Digital Combination 12.2.2 LED Display 12.2.2.1 LEDs – L-Bus Color Status green active Error 12.2.2.2 LEDs – Input Signal Color Status 1-16 yellow Sensor/Actor active green Supply OK Overload green Supply OK Overload...
  • Page 69: 3Technical Data

    ▪ Digital I/O Modules Digital Combination 12.2.3 Technical Data Inputs Number Data width in the processing image 1 Byte Inputs Current Consumption at DC 24 V nom. 10 mA Potential Insulation Voltage Insulation ▪ AC 1.5 kV outputs and electronic ▪...
  • Page 70 ▪ Digital I/O Modules Digital Combination Outputs 24 V Module Number Data Width in the Process Image 1 Byte Outputs Current Consumption at 24 V DC nom. 10 mA Output Current 2 A; 100 % ED all channels Threshold (thermic) 10 Hz at 50 % ED Safety Function inverse-polarity protection,...
  • Page 71: 4Connecting The Digital Outputs And Inputs

    ▪ Digital I/O Modules Digital Combination 12.2.4 Connecting the Digital Outputs and Inputs Connect the digital outputs and inputs via the two cage clamps X1 and X2. Follow these steps: 1. Switch off the power. 2. Connect the outputs and inputs regarding the pinassignment and the signals.
  • Page 72 ▪ Digital I/O Modules Digital Combination Cage Clamp X2 Signal Description 0 V - Potential A DI 1 Input 1 (LSB) DI 2 Input 2 DI 3 Input 3 DI 4 Input 4 DI 5 Input 5 DI 6 Input 6 DI 7 Input 7 DI 8...
  • Page 73: 5Operation

    ▪ Digital I/O Modules Digital Combination 12.2.5 Operation 12.2.5.1 Block Diagram 2x4/2x4 DC 24 V Digital Combi Module...
  • Page 74: Relay Outputs

    Relay Outputs 13.1 Characteristics ▪ Contacts are hard gold plated and not connected 13.2 Lifetime Mechanical The mechanical lifetime of the relay module is 10x10 switching cycles. (relay data) Electrical At 0.2 A, 30 V DC, a resitive load and an enviromental temperature of 85 °C the electrical lifetime of the relay module is more than 30000 switching cycles.
  • Page 75: Relay Outputs

    ▪ Digital I/O Modules Relay Outputs 13.3 6 Relay Outputs 13.3.1 Product Assembly L-Bus Interface – incoming LED-Diagnosis Display – L-Bus L-Bus Interface – outgoing LED-Diagnosis Display – Digital Outputs Connector Digital Outputs Connector Digital Outputs Neutral Conductor – Mounting Tab...
  • Page 76: 2Led Display

    ▪ Digital I/O Modules Relay Outputs 13.3.2 LED Display 13.3.2.1 LEDs – L-Bus Color Status green active Error 13.3.2.2 LEDs – Output Signal Color Status R1-R6 yellow Aktor active...
  • Page 77: 3Technical Data

    ▪ Digital I/O Modules Relay Outputs 13.3.3 Technical Data Output Relay Module Number Data Width in the Process Image 1 Byte Outputs Current Consumption at DC 24 V nom. 90 mA at DC 16,8 V 130 mA Potential Insulation Voltage Insulation ▪...
  • Page 78: 4Connecting The Relay Outputs

    ▪ Digital I/O Modules Relay Outputs 13.3.4 Connecting the Relay Outputs Connect the relay outputs via the two cage clamps X1 and X2. Proceed as follows: 1. Switch off the power. 2. Connect the outputs regarding the pin assignment and the signals. Relay Output Cage Clamp X1 Signal...
  • Page 79 ▪ Digital I/O Modules Relay Outputs Cage Clamp X2 Signal Description Relay 2, C-Contact Relay 2, NO-ontact Relay 2, NC-ontact Relay 4, C-Contact Relay 4, NO-Contact Relay 4, NC-Contact Relay 6, C-Contact Relay 6, NO-Contact Relay 6, NC-Contact Protective Earth Coding Plug Cage Clamp...
  • Page 80: 5Operation

    ▪ Digital I/O Modules Relay Outputs 13.3.5 Operation 13.3.5.1 Block Diagram Relay Outputs...
  • Page 81: Spacer

    Spacer 14.1 Characteristics ▪ Spacer for project planning ▪ Does not have any cage clamps...
  • Page 82: Product Assembly

    ▪ Digital I/O Modules Spacer 14.2 Product Assembly L-Bus Interface – incoming LED-Diagnosis Display – L-Bus L-Bus Interface – outgoing Neutral Conductor – Mounting Tab...
  • Page 83: 1Led Display

    ▪ Digital I/O Modules Spacer 14.2.1 LED Display 14.2.1.1 LEDs – L-Bus Color Status green active Error...
  • Page 84: 2Technische Daten

    ▪ Digital I/O Modules Spacer 14.2.2 Technische Daten Supply Ripple max +/- 10 % Current Consumption at DC 24 V nom. 10 mA Threshold (thermic) 10 Hz at 50 % ED Spacer Data Width in the Process Image 1 Byte inputs, content 0x00 Module Status Flag The module status flag remains “0“.
  • Page 85: Demounting

    ▪ Digital I/O Modules Demounting Demounting 1. Push the module up. 2. Pull the module from the top-hat rail. 3. Push the module down and take the module off the rail.
  • Page 86: Final Shutdown And Disposal

    ▪ Digital I/O Modules Final Shutdown and Disposal Final Shutdown and Disposal Mind the valid environmental standard of your country for the final shutdown and disposal. For the final shutdown the device has to be disassembled. Electric Parts must be disposed after the national electronic scrap regulation.
  • Page 87: Service

    ▪ Digital I/O Modules Service Service If you have any further questions regarding the product or our repairing service please contact us: Lütze Transportation GmbH Bruckwiesenstraße17-19 71384 Weinstadt Tel.: +49 (0) 7151 6053-545 Fax: +49 (0) 7171 6053-6545 Sales.Transportation@luetze.de...
  • Page 88: Appendix

    ▪ Digital I/O Modules Appendix Appendix 18.1 Overview – DIOLINE 20 Identifier Type I/O-Range Length (Bytes) (hex) 8 Digital Inputs 8 Digital Outputs 16 Digital Inputs 16DI 16 Digital Outputs 16DO 8 Digital Inputs, 8DI/8DO 8 Digital Outputs 16 Digital Inputs, 16DI/8DO 8 Digital Outputs...

Table of Contents