4.1.3 MANUAL RECOIL START
1
OPEN
4
1.
Rotate the fuel valve to the OPEN position.
2.
If the engine is cold push the choke lever to the START/CLOSED position. The
choke is used to provide the proper air-fuel mixture when the engine is cold.
You can find the choke lever behind the air filter on the back side of your
generator.
3.
Turn the power switch to the ON position.
1
4.
Pull the starter slowly until it engages then pull quickly. Repeat until the
generator starts.
5.
When the engine warms up push the choke to the RUN/OPEN position.
6.
Connect the devices to the front panel.
OPEN
4
2
START
5
RUN
2
5
25
3
6
3