Connection Draw Of: Jolly + Push-Button + Key Selector; Rrelease Knob For Jolly Electrobrake: Assembly Procedure; Transmitter And Photocells; Maintenance - RIB Jolly 20 Manual

Operator for rolling shutters balanced with springs
Hide thumbs Also See for Jolly 20:
Table of Contents

Advertisement

Available languages

Available languages

C
ONNECTION DRAW OF: JOLLY + PUSH-BUTTON + KEY SELECTOR
B
= Electrobrake
G
= Earth
If JOLLY is required complete with electrobrake, the connection of the
electrobrake to the motor is made in factory.
To connect JOLLY to J-CRX, code ABJ7080 (230/50-60Hz) or code
ABJ7079 (120/60Hz), consult the control board instructions.
In the draw you can see how connect the push button for the opening and
closing control on the inside of the premises and of the key selector for
the external control.
P
RELEASE KNOB FOR JOLLY ELECTROBRAKE: ASSEMBLY PROCEDURE
1° - Insert the steering compass (B) into the cable (A), as shown in the
drawing.
2° - Insert the sheated cable (C) along the cable (A).
3° - Insert the compass (D) onto the cable (A) as shown.
4° - Insert part (E) paying attention that part (F) has been completely
screwed.
5° - Insert the compass with the blocking screw (G) against part (F) and
tighten the hexagonal screw with a key n° 7.
6° - Fix part (H) with part (F).
To safely carry out the movement of the rolling gate it is important to
M
AINTENANCE
To be undertaken only by specialized staff after disconnecting power
supply.
Every two years it is advisable to check if the screws of the pulley and the
screw fixing to the shaft are tighten.
LN = Line 1-Phase
M
= Motor
KEY-SELECTOR
black (W)
brown (V)
blue (U)
green / yellow
G N L
U
= Common
V/W = Inverters
IMPORTANT: Use proper push button and key selector.

TRANSMITTER AND PHOTOCELLS:

- RIB can supply electronic control board for the remote control through
transmitter, push button, key selector;
- The control board can also be arranged or the connection of safety
photocell.
verify that:
- there are handles on the rolling gate;
- their position does not create dangerous points during the use;
- the manual effort to move the rolling gate must not exceed 225N for
the doors located in private sites and 390N for the doors located
in commercial or industrial sites (values indicated in point 5.3.5 of
EN 12453 standard).
ATTENTION: the activation of the release can cause an incontrollable
movement of the rolling gate in case the latter is not perfectly balanced.
Check that the springs are properly balanced and lubricate the guide with
silicone grease.
1