Electrical System

The units electrical system provides power for the
refrigeration and water systems to operate, and controls
the operational cycling of the ice maker.
115
60 HERTZ
VOLTS
L
2
1
OFF
CLEAN
6
ON
3
SERVICE
SWITCH
RECEPTACLE
BIN
THERMO-
STAT
1
3
2
EVAPORATOR
THERMOSTAT
OVERLOAD
COMPRESSOR
TRANSFORMER
115 V
8.5 V
DOOR SWITCH
CUTTER GRID
Figure 3-11. Electrical System
Unit with an FSP condensate pump installed.
115
60 HERTZ
VOLTS
L
2
1
OFF
CLEAN
6
ON
3
SERVICE
SWITCH
RECEPTACLE
BIN
THERMO-
STAT
1
3
2
EVAPORATOR
THERMOSTAT
OVERLOAD
COMPRESSOR
TRANSFORMER
115 V
8.5 V
DOOR SWITCH
CUTTER GRID
Figure 3-12. FSP Condensate Pump Diagram
N
WATER
PUMP
PLUG
CONDENSER
FAN
HOT
N.C.
GAS SOLENOID
N.C.
WATER
PRESSURE
SHUNT
VALVE
SWITCH
SOLENOID
R
S
CONDENSATE
DRAIN PUMP
START RELAY
UNIT SHOWN WITH GRAVITY DRAIN;
SERVICE SWITCH IN "OFF" POSITION;
BIN NOT FULL OF ICE.
N
WATER
PUMP
PLUG
CONDENSER
FAN
HOT
N.C.
GAS SOLENOID
N.C.
WATER
PRESSURE
SHUNT
VALVE
SWITCH
SOLENOID
R
S
CONDENSATE
DRAIN PUMP
START RELAY
UNIT SHOWN WITH GRAVITY DRAIN;
SERVICE SWITCH IN "OFF" POSITION;
BIN NOT FULL OF ICE.
Units using a non-FSP sump pump.
The sump pump is powered directly from an independ-
ent electrical power supply and is not controlled by the
ice maker.
115
VOLTS
L
2
1
OFF
CLEAN
6
ON
3
SERVICE
SWITCH
BIN
THERMO-
STAT
1
3
2
EVAPORATOR
THERMOSTAT
OVERLOAD
TRANSFORMER
CUTTER GRID
Figure 3-13. Non FSP Sump Pump Diagram
3-7
Theory of Operation
60 HERTZ
N
WATER
PUMP
PLUG
CONDENSER
FAN
RECEPTACLE
HOT
N.C.
GAS SOLENOID
N.C.
WATER
PRESSURE
SHUNT
VALVE
SWITCH
SOLENOID
R
S
CONDENSATE
DRAIN PUMP
COMPRESSOR
START RELAY
115 V
8.5 V
UNIT SHOWN WITH GRAVITY DRAIN;
SERVICE SWITCH IN "OFF" POSITION;
BIN NOT FULL OF ICE.
DOOR SWITCH
#3752200 - Revision B - May, 2006