Electrical Requirements; Installation Specifications - Sub-Zero UC-15I Service Manual

Undercounter ice machine
Hide thumbs Also See for UC-15I:
Table of Contents

Advertisement

Installation Information

ELECTRICAL REQUIREMENTS

Prepare electrical circuit before installation of the ice
machine. Installation requires a grounded (three-
prong), polarized receptacle
separate fuse/circuit breaker in an electrical service
box.
Proper Three-Prong Polarized Receptacle
NOTE:
All National Electrical Code regulations must be
followed. In addition, be aware of local codes and ordi-
nances when installing the services.
Voltage
ELECTRICAL SHOCK HAZARD. DO NOT USE AN
EXTENSION CORD OR TWO PRONG ADAPTER.
ELECTRICAL GROUND IS REQUIRED ON THIS
APPLIANCE. DO NOT REMOVE THE POWER SUP-
PLY CORD GROUND
PRONG.
All electrical work, including wire routing and grounding,
must conform to local, state and national electrical
codes. The following precautions must be observed:
• The ice machine must be grounded.
• A separate fuse/circuit breaker must be
provided for each ice machine.
• The maximum allowable voltage variation
is +/-10% of the rated voltage at ice
machine start-up (when the electrical load
is highest).
#7012423 - Revision B - May, 2011
Model UC-15I (Undercounter Ice Machine)
(See Figure
2-2), with a
• The minimum wire size is #14 for less than 100 feet
(30.5 m) or #12 for more than 100 feet (30.5 m) to
200 feet (61 m) (solid copper conductor only). The
recommended breaker is 15 amp. Local or state
electrical code, length of run or materials used, can
increase the minimum wire gauge required. A quali-
fied electrician must determine the proper wire size,
although #14 is the minimum size allowed.
NOTE:
Observe correct polarity of incoming line volt-
age. Incorrect polarity can lead to erratic ice machine
operation and a safety issue.
Minimum Circuit Requirements
The minimum circuit requirement is used to help select
the wire size of the electrical supply.
NOTE:
Minimum Circuit Amps listed below is not the
ice machine's running amp load.
MAXIMUM BREAKER SIZE AND
MINIMUM CIRCUIT AMPERAGE
Voltage / Phase / Cycle
Maximum Fuse/Circuit Breaker Amps
Minimum Circuit Amps
GFCI Requirements
For Models UC-15IO and UC-15IPO or if a GFCI
(ground fault circuit interrupter) is required by local elec-
trical code, it must be breaker type.

INSTALLATION SPECIFICATIONS

1
15
OPENING WIDTH
POSITION OUTLET
ELECTRICAL
WITH GROUNDING
PRONG ON RIGHT
SHADED AREA
FRONT VIEW
Dimensions in parentheses are in millimeters unless otherwise specified.
2-4
/
"
4
min (387)
ROUGH
LOCATE
WITHIN
4"
( 102 )
115 / 1 / 60
15
4.1
1
34
/
"
2
(876)
ROUGH
OPENING
HEIGHT
5
33
/
"
8
(854)
MINIMUM
HEIGHT
REQUIRED

Advertisement

Table of Contents
loading

Table of Contents