Technical Data - Sub-Zero Wolf 506UI Service Manual

Undercounter icemaker
Table of Contents

Advertisement

Technical Data

Model 506 Undercounter Icemaker
Water Solenoid Valve - .25 GPM Flow Washer - 80 Mesh Inlet Screen
Water Pump Motor - 39 Watts, .75 Amps, 3350 RPS
(Water distributor uses restricted inlet to obtain proper pump capacity)
Compressor Overload - Current and Ambient Sensitive
Compressor Relay - Current (magnetic) Type with N/O Start Contact
Condenser - Forced Air - Copper & Aluminum
Evaporator - Stainless Steel
Refrigerant Charge (R -12) - See Serial Plate
Drier - Molecular Sleeve - High Side
Running Amps - 3.5 (average)
Bin Storage Capacity - 35 Lbs. Maximum
Ice Production Capacity - See Ice Production Chart Below
THERMOSTAT
Ice Thickness (Evaporator)
Warm Position →
Bin Shut -off
IMPORTANT NOTE:
is "S" shaped and laying tight against the bracket soldered to the bottom of the evaporator. Tape at least 1"
of capillary tube to the hot gas line at the front edge of the evaporator. This shortens the defrost time.
ICE PRODUCTION (Lbs.) IN 24 HOURS
100°F
35
90°F
42
44
80°F
70°F
46
50°F
Water Temperature
Temperature (Fahrenheit)
Ambient 70 °/ Water 60 °
Ambient 90 °/ Water 60 °
Ambient 100 °/ Water 60 °
Ambient 70 °/ Water 80 °
Ambient 90 °/ Water 80 °
Ambient 100 °/ Water 80 °
#3752200 - Revision B - May, 2006
CUT-IN
38°F " 2°F
38°F " 2°F
41 °F " 1.5°F
When changing an evaporator thermostat, make sure that at least 8" of capillary tube
34
33
32
40
38
36
41
39
34
42
39
35
60°F
70°F
80°F
PERFORMANCE DATE
Suction Pressure
at end of Freeze Cycle
4 - 7
5 - 8
6 - 9
4 - 7
5 - 8
6 - 9
Model 506 (UC Ice Maker)
Model 506 (UC Ice Maker)
(Prior to Serial # 1181341)
- Internal Overload
CUT- OUT
10.5°F " 4°F
-3°F " 2.5°F
35°F " 1.5
NOTE:
Maximum ice production will only be obtained under ideal
conditions. Production capacities shown in the above graph are
average and variances are normal.
Additional factors which reduce the production capacity are:
1. Making cubes thicker than 1/2".
2. Increased ice meltage in storage bin due to high ambient
temperatures (25% is average).
To maintain production capacity, avoid locating icemaker in
greasy or dusty atmosphere, or adjacent to high temperature
equipment such as ovens, ranges, steam tables, etc. . .
Head pressure
at end of Freeze Cycle
110 - 125
145 - 160
185 - 200
110 - 125
145 - 160
185 - 200
7-2
ALTITUDE CORRECTION
Adjust range screw
according to chart on unit
thermostat bracket
Cycle Time in Minutes
25 - 29
27 - 33
38 - 46
28 - 34
32 - 40
40 - 48

Advertisement

Table of Contents
loading

Table of Contents